background image

IS-OR-Rionfuse CF 2318

EDP# 1915462

© 2023 Watts 

NOTICE 

Inquire with governing authorities for local installation 

requirements. 

Limited Warranty: 

Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and 

workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects 

within the warranty period, the Company will, at its option, replace or recondition the product without charge. 

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH 

RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY 

HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO 

THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of 

warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without 

limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work 

properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage 

from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty 

shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of 

the product. 

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion 

or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited 

Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult 

applicable state laws to determine your rights.

 SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED 

WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL 

SHIPMENT. 

USA:

 T: (800) 334-6259 • OrionFittings.com 

Canada: 

T: (888) 208-8927 • OrionFitting.ca 

Latin America: 

Tel: (52) 55-4122-0138 • OrionFittings.com 

Summary of Contents for RionFuse CF

Page 1: ...ent Keep this Manual for future reference DANGER Electricity electrocution and shock hazards WARNING Local building or plumbing codes may require modifications to the information provided You are requ...

Page 2: ...e has passed This will not prevent the processor from performing fusions however the processor should be calibrated as soon as possible NOTICE The correct output voltage cannot be assured if the proce...

Page 3: ...tput cable ends User accessible fuse Emergency stop switch Can store fusion information for 1 000 fusions Model RF 3000LE Specification Hermetically sealed joints conforming to ASTM F1290 Technique 1...

Page 4: ...pipe fitting to insure that the coupling is properly positioned during the fusion cycle Then using 60 grit emery cloth abrade the marked ends of the pipe and fitting to remove the natural sheen of th...

Page 5: ...e pipe during the fusion process With the Rionfuser unit connected to a dedicated power source and powered ON connect the lead cables to the coupling Connect lead cables Step 5 Selecting Fitting Style...

Page 6: ...nce the parameters have been verified press START to begin the fusion weld Fusion cycle type selection screen Step 9 Successful Weld Completion After pressing START the Rionfuser will begin the weld A...

Page 7: ...le from Orion Engineering Department To download fusion data from the processor to a USB flash drive perform the following steps 1 Turn on the processor and allow it to proceed through the INTERNAL SE...

Page 8: ...e processor This AC power wource should Be well maintained and subjected to a periodic maintenance schedule Provide output voltage within the specified operating range Contain a matching outlet which...

Page 9: ...soon as it starts to display this reminder message On the date that calibration is due the processor will display Error 113 Calibration Required and stop fusing until it is calibrated When the RF 3000...

Page 10: ...ation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fou...

Page 11: ...ult rieure DANGER Pr sence d lectricit risque d lectrocution et de d charges lectriques AVERTISSEMENT Il se peut que les codes du b timent ou de plomberie locaux n cessitent des modifications aux info...

Page 12: ...usions cependant le processeur doit tre talonn d s que possible AVIS La tension de sortie correcte ne peut tre garantie si le processeur n est pas talonn au moins une fois tous les deux 2 ans Coordonn...

Page 13: ...teur Interrupteur d arr t d urgence Peut stocker les informations de fusion pour 1 000 fusions Mod le RF 3000LE Sp cifications Des joints herm tiques conformes la norme ASTM F1290 Technique 1 doivent...

Page 14: ...ite en utilisant une toile d meri de grain 60 poncez les extr mit s marqu es du tuyau et du raccord pour retirer le lustre naturel du plastique Lorsque c est fait nettoyez soigneusement toutes les sur...

Page 15: ...processus de fusion L unit Rionfuser tant connect e une source d alimentation d di e et mise sous tension branchez les c bles sur l accouplement Brancher les c bles tape 5 S lection du style de raccor...

Page 16: ...es param tres ont t v rifi s appuyez sur START pour commencer le soudage par fusion cran de s lection du type de cycle de fusion tape 9 R ussite du soudage Apr s avoir appuy sur START le Rionfuser com...

Page 17: ...RF 3000LE USB ou Rionfuser LT sont t l charg es sur un lecteur flash USB externe Les donn es sont sorties dans un format binaire compatible avec une feuille de calcul Excel macro gratuite disponible...

Page 18: ...tretenue et soumise un programme de maintenance p riodique Fournir une tension de sortie dans la plage de fonctionnement sp cifi e Comporter une prise de courant adapt e qui doit tre connect e la fich...

Page 19: ...nce s afficher la date laquelle l talonnage doit tre effectu le processeur affiche Erreur 113 talonnage requis et arr tera la fusion jusqu ce qu il soit talonn Lorsque le processeur d lectrofusion RF...

Page 20: ...ts de r paration ou de remplacement des autres biens ayant t endommag s si ce produit ne fonctionne pas correctement autres co ts aff rents aux frais de main d uvre de retards de vandalisme de n glige...

Page 21: ...nsultas posteriores PELIGRO Riesgo de electricidad descarga el ctrica y choque el ctrico ADVERTENCIA Los reglamentos locales de construcci n o plomer a pueden requerir modificaciones a la informaci n...

Page 22: ...rocesador realice fusiones Sin embargo el procesador debe calibrarse lo antes posible AVISO No se puede garantizar el voltaje de salida correcto si no se calibra el procesador al menos una vez cada do...

Page 23: ...o Fusible accesible para el usuario Interruptor de parada de emergencia Puede almacenar informaci n de fusiones para 1000 fusiones Modelo RF 3000LE Especificaci n Las juntas selladas herm ticamente de...

Page 24: ...n Luego con la malla de esmeril de grano 60 lije los extremos de la tuber a y aco plamientos marcados para quitar el brillo natural del pl stico Despu s del lijado limpie bien todas las superficies de...

Page 25: ...de energ a exclusiva y encendida conecte los cables principales al acoplamiento Conecte los cables conductores Paso 5 Seleccione el estilo de acoplamiento La unidad ahora pedir al instalador que sele...

Page 26: ...los par metros presione START para empezar la soldadura por fusi n Pantalla de selecci n del tipo de ciclo de fusi n Paso 9 Terminaci n exitosa de la soldadura Luego de presionar START el Rionfuser i...

Page 27: ...ten en un formato binario que es compatible con una hoja de c lculo Excel con macros gratuita disponible en el Departamento de Ingenier a de Orion Para descargar los datos de fusi n del procesador a u...

Page 28: ...CA debe Recibir el correcto mantenimiento y estar sujeta a un programa de mantenimiento peri dico Proporcionar voltaje de salida dentro del rango de funcionamiento especificado Contener un tomacorrie...

Page 29: ...braci n tan pronto como comience a mostrar este mensaje recordatorio En la fecha de vencimiento de la calibraci n el procesador mostrar Error 113 Calibraci n requerida y dejar de fusionar hasta que se...

Page 30: ...ienes da ados si este producto no funciona correctamente otros costos resultantes de cargos laborales retrasos vandalismo negligencia contaminaci n causada por materiales extra os da os por condicione...