background image

Instructions for Installing

FD-190-PR/190-PR-60 &

FD-290-PR/290-PR-60

Pronto!™ Adjustable Cast Iron and PVC
Floor Drains

IS-WD-FD-190/290-PR

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

Watts Pronto!™ floor drains are designed for pre- and post-pour adjustment with flexibility in mind. 
Pronto!™ delivers an integrated built-in bubble level for ease of installation and is pre-packaged with 
shims for tilt correction.
Pronto!™ is designed for light to medium commercial and residential applications and comes in
both cast iron and PVC. PVC drains offer the unique ability for easy installation while giving durability 
for the long haul. Cast iron is durable and designed with ease of installation in mind. Both drains are 
adjustable and meet the requirements of a durable adjustable floor drain.

Installation Guidelines

Local building or plumbing codes may require modifica-

tions to the information provided.  You are required to  

consult the local building and plumbing codes prior 

to installation.  If the information provided here is not 

consistent with local building or plumbing codes, the 

local codes should be followed.  This product must be 

installed by a licensed contractor in accordance with 

local codes and ordinances.

WARNING

!

Label Protection for Top of Cap

Plastic Cap with Bubble Level

Nickel Bronze Grate

Shims for Leveling

Nickel Bronze

Grate Ring

PVC/CI Strainer

Shank

PVC/CI Shank

Housing

PVC/CI Clamp

Collar

PVC/CI

B4-34 Body

PVC/CI
B3-Body

General Note: 

Please consult all local plumbing codes before installing 

Watts Pronto!™ floor drains.

FD-190

Body

FD-290

Body

Summary of Contents for Pronto! FD-190-PR-60

Page 1: ...ile giving durability for the long haul Cast iron is durable and designed with ease of installation in mind Both drains are adjustable and meet the requirements of a durable adjustable floor drain Ins...

Page 2: ...y disassembled before installation Plastic top assembly with bubble level should remain on the drain until drain is securely installed and concrete cured The plastic top assembly is designed to keep t...

Page 3: ...ete 3 4 Waterproofing Membrane Waterproofing membrane is used per the manufacturers instructions Clamping collar must be removed while installing waterproofing membrane Waterproofing membrane sits on...

Page 4: ...bble Level Recessed Slot Recessed Slot 5 Plastic Top Assembly Adjust the top of the drain with the plastic cover in place by screwing it into the drain body until the top of the cover is flush with fi...

Page 5: ...of the strainer frame Gently turn the head clockwise until the top of the strainer sits flush with the finish floor 0 7 8 Adj After Pour 3 3 8 85 Adjust After Concrete Pour Continue tapping until a v...

Page 6: ...ot work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over w...

Page 7: ...uradero y est dise ado teniendo en cuenta la facilidad de instalaci n Ambos drenajes son ajustables y cumplen los requisitos de un drenaje de piso ajustable y duradero Lineamientos de instalaci n La i...

Page 8: ...l ensamble superior de pl stico con nivel de burbuja debe permanecer en el drenaje hasta que el drenaje est bien instalado y el concreto haya curado El ensamble superior de pl stico est dise ado para...

Page 9: ...4 Membrana impermeabilizante La membrana impermeabilizante se usa de acuerdo con las instrucciones del fabricante El collar de fijaci n se debe retirar mientras se instala la membrana impermeabilizan...

Page 10: ...Ranura ahuecada 5 Ensamble superior de pl stico Ajuste la parte superior del drenaje con la cubierta de pl stico en su lugar atornill ndola en el cuerpo del drenaje hasta que la parte superior de la c...

Page 11: ...tido de las manecillas del reloj hasta que la parte superior del filtro quede nivelada con el piso terminado 0 7 8 0 22 mm de ajuste despu s del vaciado 3 3 8 85 mm Ajustar despu s de vaciar el concre...

Page 12: ...que resulten de cargos laborales retrasos vandalismo negligencia mal olor ocasionado por materia extra a da o por condiciones adversas del agua sustancias qu micas o cualquier otra circunstancia de l...

Page 13: ...tout en offrant une durabilit long terme La fonte est durable et con ue pour la facilit d installation Les deux drains sont r glables et r pondent aux exigences d un drain de plancher r glable et dur...

Page 14: ...installation L ensemble sup rieur en plastique avec le niveau bulle doit rester sur le drain jusqu ce que le drain soit solidement install et que le b ton soit durci L ensemble sup rieur en plastique...

Page 15: ...ane d tanch it La membrane d tanch it est utilis e conform ment aux instructions du fabricant Le collier de serrage doit tre retir lors de l installation d une membrane d tanch it La membrane d tanch...

Page 16: ...nte encastr e Fente encastr e 5 Ensemble sup rieur en plastique R glez le haut du drain avec le couvercle en plastique en place en le vissant dans le corps du drain jusqu ce que le haut du couvercle s...

Page 17: ...doucement la t te dans le sens horaire jusqu ce que le haut de la cr pine soit gal au plancher fini Ajustement de 0 7 8 po 0 22 mm apr s le versement 3 3 8 85 Ajustez apr s le versement du b ton Conti...

Page 18: ...orrectement autres co ts aff rents aux frais de main d uvre de retards de vandalisme de n gligence d engorgement caus s par des corps trangers dommages caus s par des propri t s de l eau d favorables...

Reviews: