6.2.
Lync UV Maintenance
UV Lamps have a
1 year (9000 Hour) life span
under normal operating conditions. Quartz
sleeves should be cleaned with vinegar, citric acid, or a lime scale removing chemical annually
and replaced no less than once every 3 years. If the quartz sleeve cannot be cleaned, or if it is
discolored, is must be replaced. Pre filters should be maintained according to the
manufacturer’s instructions to ensure feed water requirements within this manual are met.
Lamp and Quartz Sleeve Replacement Procedure
WARNING!
If any water comes in contact with any electrical components, dry the components
immediately.
DO NOT energize a system with damp or wet electrical components.
1. Disconnect the power supply from the wall outlet.
2. Turn off the inlet valve and outlet isolation valves.
3. Disconnect the lamp lead wire from the glow cap electrical port. (A).
4. Rotate the glow cap counter clockwise to unlock it from the mounting bracket. (B).
5. Pull up on the glow cap to remove the lamp from the quartz sleeve. (C). If not replacing
the quartz sleeve proceed to step 11.
6. De-pressurize the system.
7. Grip the quartz sleeve nut with your hand and unscrew counter clockwise until it can be
lifted from the reactor chamber's threaded port. (D).
8. Remove the quartz sleeve from reactor chamber. (E).