2

System Specifications

Maximum Pressure: 

All Systems - 100psi (6 .8 bar)
Minimum Pressure: 

All Systems - 20psi (1 .4 bar)  
Maximum Temperature: 100°F (38°C) 

Minimum Temperature: 40°F (4 .4°C)
Feed Water Quality: pH 6 .5 to 8 .5
Chlorine < 2ppm
Iron (maximum) 0 .3 mg/l
Manganese (maximum) 0 .05 mg/l
Oil & H2S- None allowed
For all other feed water quality requirements abide by the current 

USEPA Safe Drinking Water Act standards .
Inlet/Outlet Connections: 1/2" (15mm) NPT 
Maximum Flow Rate: 

System Flow Rate and Capacity

System Model

Flow Rate

Chlorine Capacity

QTESPMAX-2S-10M

1 GPM (3.8 LPM)

20,000 Gallons

QTESPMAX-3S-10M

2 GPM (7.6 LPM)

20,000 Gallons

QT Espresso Max line is available in different configurations depend-

ing upon filtration and flow requirements . 

System Replacement Filters

System Model

Filter Ordering Code

Frequency

Description

QTESPMAX-2S-

10M

ESPMAXR-L-CB

6 Months

20" 5 Micron Coconut Shell 

Carbon Block

QTES15

As Needed

15" Cation Exchange Water 

Softening Filter

QTESPMAX-3S-

10M

ESPMAXR-L-CB

6 Months

20" 5 Micron Coconut Shell 

Carbon Block

QTES15

As Needed

15" Cation Exchange Water 

Softening Filter (2)

NOTICE

Filter cartridges should be changed at end of filter life, due to lack of 

filtering performance, or whenever a 15 psi pressure drop or greater 

is experienced during normal operation, whichever comes first .
For all replacement filters and components contact your authorized 

Hydro-Safe foodservice representative .

Cartridge capacities are estimates and may be less depending  

on incoming water quality .

Notice to Installers

•  Water Temperature cannot exceed 100°F (38°C) .
•  System must be installed in a vertical, upright and level position . 
•  Do not use with water that is microbiologically unsafe or of  

unknown water quality .

•  Notice to user/owner/operator: Please retain this manual for future 

reference for parts, maintenance, or troubleshooting .

•  It is recommended that all personnel responsible for operation and 

maintenance of this product read the precautions, maintenance, 

and operation sections of this manual .   

Installation Precautions

•  Do not install system on line pressure above the rated pressure as 

noted in System Specifications above .

•  Do not install the system on a hot water line . Failure to limit the 

water temperature to 100°F (38

°

C) can result in housing failure and 

property damage .

•  Do not connect the system backwards with the feed water line 

connected to the outlet . 

•  Do not use liquid pipe thread compounds for threaded  

connections . Use Teflon

®

 tape only .

•  Do not solder plumbing connections that are attached to the  

housings or inlet/outlet fittings . System damage may occur due to 

high temperature .

•  Do not allow the system to freeze . Turn off water supply and drain 

the system if temperature falls below 32°F (0

°

C) . 

•  Do not install system in direct sunlight or where the system will be 

exposed to harsh chemicals or may be subjected to being hit by 

moving equipment, carts, mops, or any other item that may cause 

damage . 

•  Allow 3" (76mm) minimum clearance under the housings for filter 

replacement . 

•  If water hammer is evident, install water hammer arrestors before 

the system . 

•  Do not over tighten fitting connections . 
•  Always back up valves and fittings with a wrench when installing 

fittings to avoid over tightening or loosening existing fittings . 

•  Do not install the unit behind equipment where it may be difficult to 

access the system for future filter replacements . 

Position the system in a suitable location . The direction of flow 

through the system is left to right . Keep this in mind when determin-

ing installation locations . Do not mount the system near any source 

of heat . Also do not mount this system over anything that may be 

adversely affected by water .  

Operation

With sufficient pressure, operation of this system is completely auto-

matic . Dependable operation involves only monitoring system pres-

sure differential, periodic filter changes, and service documentation .   

Installation

There is some light field assembly required for this system. Be-

fore beginning the installation of this system, please make sure 

all components are present. Compare the contents of this box 

to the system drawings located at the end of this manual. These 

drawings will be referenced in the installation instruction steps. 

  1 .   Turn off all equipment to be fed by the system, locate the water 

supply shutoff valve and turn it off .

  2 .   Apply Teflon tape to the threads of the inlet and outlet valve 

assemblies and pressure gauges . 

DO NOT USE PASTE TYPE 

THREAD SEALANT.

 Thread the inlet and outlet valve assem-

blies into the inlet and outlet ports of the system as shown on 

the system drawings in this manual . Install the pressure gauges 

into the gauge ports as indicated by the system drawings in this 

manual . 

DO NOT OVER TIGHTEN THESE FITTINGS INTO THE FILTER 

HEADS.

 When installing fittings onto this system, back any existing 

receiving fittings with a wrench to prevent fitting movement . Use a 

wrench to tighten gauges into their connection ports . Do not twist on 

gauge case .

Replacement Filters

NOTICE

NOTICE

NOTICE

IOM-HS-QTEspressoMax.indd   2

8/30/17   1:16 PM

Summary of Contents for Hydro-Safe QTESPMAX-2S-10M

Page 1: ...Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipment Keep this Manual for future reference You are required to consult the local building and plumbing codes prior to installation If the information in this manual is not consistent with local building or plumbing codes the ...

Page 2: ...threaded connections Use Teflon tape only Do not solder plumbing connections that are attached to the housings or inlet outlet fittings System damage may occur due to high temperature Do not allow the system to freeze Turn off water supply and drain the system if temperature falls below 32 F 0 C Do not install system in direct sunlight or where the system will be exposed to harsh chemicals or may ...

Page 3: ...anged at end of filter life due to lack of filtering performance or whenever a 15 psi pressure drop or greater is experienced during normal operation whichever comes first Filter Cartridge Replacement Procedure Determine whether all equipment connected to the system must be turned off prior to shutting off water supply from filters 1 If required turn off downstream equipment 2 Turn OFF water to th...

Page 4: ...ng other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Company has no control This warranty shall be invalidated by any abuse misuse misapplication improper installation or improper mainten...

Reviews: