Typical Mounting Instructions For Pre-Rinse Assembly
1.
PRE-RINSE ASSEMBLY
LESS ADD-ON FAUCET
a. Turn off the water supply at
the source.
b. Apply pipe joint compound or
teflon tape to threads on both
ends of riser pipe. Thread
riser pipe into faucet body
and hand tighten.
1A.
PRE-RINSE ASSEMBLY
WITH ADD-ON FAUCET
a. Turn off the water supply at
the source.
b. Apply pipe joint compound or
teflon tape to threads on end of
short riser pipe attached to
add-on faucet. Thread riser pipe
into faucet body and tighten.
c. Apply pipe joint compound or
teflon tape to threads on both
ends of riser pipe.Thread riser
pipe into add-on faucet body
and hand tighten.
RISER
PIPE
TEFLON TAPE
OR PIPE JOINT
COMPOUND
FAUCET BODY
2. ASSEMBLE SPRAY HEAD
HOOK TO RISER
Spread (open) clamp section
of hook so that it will slide
over riser without marking
finish of riser. Orient spray
head hook with hook facing
up and assemble to riser.
Place approximately one
half down length of riser.
Do not tighten
at this time.
RISER PIPE
CLAMP
SPRAY HEAD
HOOK
RISER PIPE
ADD-ON FAUCET
SHORT
RISER PIPE
FAUCET BODY
POSITIVE SEAL
O-RING
CONSTRUCTION
ELIMINATES NEED
FOR WASHERS
SPRING
RETAINER
STRAIN
RELIEF
SPRING
HOSE
COUPLING
LARGE COIL
SPRING
HOSE
SPRAY
HEAD RING
SPRAY HEAD
GRIP
WRONG
DIRECTION
CORRECT
DIRECTION
BE SURE O-RING IS INSTALLED FOR
PROPER PERFORMANCE
(Extra O-rings are provided)
HOSE
COUPLING
GRIP
#1
#2
Dormont warrants to Buyer that Watts Hydro-Force™ Economy
commercial foodservice products (the “Product”) will be free from
defects in material and workmanship for a period of two years from
the date of delivery to the Buyer. For items not manufactured by
Dormont, the only warranty extended is that of the manufacturer, if
any. In the event of defects within the warranty period, Dormont will
replace the Product or other items at Dormont’s expense (excluding
labor and freight charges).
To qualify for the warranty remedy stated above, you must obtain
return authorization from Dormont and return the defective Product
or other items in accordance with Dormont’s shipping instructions.
All defective returns shall be subject to Dormont’s inspection and
approval. This Product and any other items must be installed by
individuals trained and certified as professionals with respect to
such installation, and be installed, used, repaired and maintained
by Buyer in accordance with local codes or regulations, and
standards set by NSF. Any failure to observe these requirements
shall void this Limited Warranty. The Product and other items
are warranted in conjunction with the original installation or
connection only. Buyer shall not assign its rights under this
Limited Warranty and any attempted assignment shall render this
warranty, but not any disclaimers or limitations, void.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND
IS THE ONLY WARRANTY GIVEN BY DORMONT WITH RESPECT
TO THE PRODUCT. DORMONT MAKES NO OTHER WARRANTIES,
EXPRESS OR IMPLIED. DORMONT HEREBY SPECIFICALLY
DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this Limited Warranty
shall constitute the sole and exclusive remedy for breach of warranty,
and Dormont shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or
the cost of repairing or replacing other property which is damaged if
the Product or other items do not work properly, other costs resulting
from labor charges, delays, vandalism, negligence, fouling caused
by foreign material, damage from adverse conditions, chemicals, or
any other circumstances over which Dormont has no control. This
warranty shall be invalidated by any abuse, misuse, misapplication,
improper installation, improper maintenance, alteration or repair of
the Product or items, damage caused by shipping or conformity of the
Product to local codes or regulations not previously made known to
Dormont, or other occurrences or conditions other than normal use .
Some States do not allow limitations on how long an implied warranty
lasts, and some States do not allow the exclusion or limitation of
incidental or consequential damages. Therefore the above limitations
may not apply to you. This Limited Warranty gives you specific legal
rights, and you may have other rights that vary from State to State.
You should consult applicable state laws to determine your rights.
SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW,
ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED,
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN
DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.
LIMITED WARRANTY
4. ASSEMBLE PRE-RINSE WITH GOOSENECK SPRING
a. Assemble spring retainer to riser pipe and tighten with wrench. This will also tighten riser pipe on faucet body.
b. Assemble hose to spring retainer. Ensure O-ring is in place inside of hose coupling prior to assembly.
(Refer to drawing #1 below). Additional O-rings are provided for future use. Tighten securely.
c. Assemble large coil spring over hose and onto spring retainer.
IMPORTANT: Spring must be assembled
vertically with large curve of spring to the top.
d. Assemble spray head ring over spray head grip, and assemble spray head assembly to hose.
Tighten with wrench; ensure O-ring is in place prior to assembling. (Refer to drawing #2 below).
Note:
Realign spray head hook on riser and tighten. Tighten all wall bracket screws.
Turn on water and check for leaks.
3. ASSEMBLE WALL BRACKET
Model No. LFPRA-WB
Determine correct length of support
rod from wall to riser pipe. Cut
rod to approximate size. Affix wall
bracket base securely to wall. Install
compression nut and bracket ferrule
and tighten securely.
NOTE:
WALL BRACKET SHOULD BE LOCATED TOWARD TOP OF
RISER PIPE– AS CLOSE AS POSSIBLE TO SPRING RETAINER.
WALL
BRACKET BASE
COMPRESSION
NUT
FERRULE
SUPPORT
ROD
SPRING
RETAINER
RISER PIPE
CAUTION!
MANUFACTURER RECOMMENDS THE
USE OF WALL BRACKET ASSEMBLY TO SECURE
RISER PIPE ON ALL PRE-RINSE ASSEMBLIES.
IOM-Hydro-Force Economy 1810
© 2018 Watts
USA:
T: (800) 367-6668 • F: (724) 733-4808 • foodservice.watts.com
Canada:
T: (905) 332-4090 • F: (905) 332-7068 • foodservice.watts.com
Summary of Contents for Hydro-Force LFFRRV-H-C
Page 11: ......