IS-HF-M100+-29293  Rev 5

 

2

 

Attention Owners and Users

Thank you for purchasing the M100+™ turbidimeter. This equipment will provide safe and productive operation as long as it is installed, used, 

maintained, and serviced in accordance with the instructions in this manual and is properly maintained. Importantly, unless the user is adequately 

trained and supervised, there is a possibility of a personal injury, property damage or damage to the equipment.
Owners and users of this equipment bear the responsibility to make certain that this equipment is used properly and safely. READ THIS MANUAL 

carefully, learn how to use and service this equipment correctly, and strictly follow all of the instructions contained in this manual and the 

requirements of local, state and federal law. Failure to do so could result in personal injury, property damage or damage to the equipment. This 

manual should be considered a permanent part of your machine and should be kept available for easy reference by any user.
Owners should not permit anyone to touch this equipment unless they are over 18 years of age, are adequately trained and supervised, and have 

read and understood this manual. Owners should also ensure that no unauthorized personnel comes in contact with this equipment.
If this equipment, or any of its parts, becomes damaged or needs repair, stop using the equipment and contact an experienced service individual 

immediately. If the warning labels or this manual are misplaced, damaged or illegible, or if you require additional copies, please contact customer 

service at +1-239-337-2116 or 888-203-7248 for these items at no charge.
Please remember that this manual and the warning labels do not replace the need to be alert, to properly train and supervise users, and to use 

common sense when using this equipment. 
If you are ever uncertain about a particular task or the proper method of operating this equipment, ask your supervisor, consult this manual, access 

www.wattswater.com, or contact customer service.

Product Identification

Please record your product’s identification and purchase information which will help in the event you have questions or need any service.

Model:

Date of Purchase:

Serial #:

Seller Name/Address:

Summary of Contents for HF scientific M100 28060

Page 1: ...een Calibration 6 Set Date Time 6 Delete Samples 6 Data Resolution 6 Offset 7 Device ID 7 Calibration Reminder 7 Calibration Download 7 Firmware Update 7 Reset Defaults 7 About Device 7 Calibrating th...

Page 2: ...ould not permit anyone to touch this equipment unless they are over 18 years of age are adequately trained and supervised and have read and understood this manual Owners should also ensure that no una...

Page 3: ...t in death or serious injury This symbol identifies hazards which if not avoided could result in death or serious injury This symbol identifies hazards which if not avoided could result in minor or mo...

Page 4: ...ns for the M100 are valid only for measurement of static non flowing samples Touch Screen Standard Inserted in Optics USB Connector Unpacking and Inspection of the Instrument Remove all items from pac...

Page 5: ...gned to provide the ability to customize the instrument according to your needs at any time during normal operation The Setup screen has been split into sub menus to facilitate instrument configuratio...

Page 6: ...ation The screen has been factory adjusted but can be adjusted if the alignment is off The screen may need to be calibrated if new software has been downloaded It is a 5 position setup 1 Press the Set...

Page 7: ...sert the USB memory stick that contains the software into the USB port 3 If the firmware revision on the memory stick is older than the firmware currently installed the instrument will ask if you wish...

Page 8: ...ded as general guidelines for proper care of ProCal standards Standards should only be handled by the top black cap or by the very bottom of the cuvette Keep cuvette glass clean of fingerprints and de...

Page 9: ...n on the left side of the screen 2 Insert the 4000 NTU standard 3 Press the Command button in the middle of the screen to start calibration A countdown from 30 will appear on the screen When the count...

Page 10: ...stic Banner On Off Reading List Setup Calibration Trend Home Data Retrieval Data logging can only save 100 points per Sample ID All data is saved in CSV format and is date and time stamped Sample ID D...

Page 11: ...Email HF Info wattswater com www hfscientific com Routine Maintenance Routine maintenance should include calibration of the instrument See Calibration section in this manual for more information Clea...

Page 12: ...al or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting...