6 Month System Maintenance

Step 1     

Step 3

Let system sit for one minute after the tank is empty to let the 

system depressurize before attempting to remove filter housings.

Items needed:

√ 

Stage 1 - Sediment Filter 

√ 

Stage 2 - Carbon Block Filter

Turn off the incoming water supply to the RO system at the adapt-a-

valve. 

Open the RO Faucet and allow water to drain from the tank until it is 

completely empty.

Step 2

Note:

Water may be saved in a container for drinking or to rinse 

system parts.

For more leverage you may leave the RO System attached to wall of 

cabinet.  If you are unable to access the module while it is mounted, 

remove it prior to changing filters. Starting with the sediment pre-filter 

housing Stage 1, remove it by turning it clockwise (left), empty water, 

then discard filter. Continue on to the carbon pre-filter

 

housing Stage 2.

Step 4

Clean the filter housings (bowls) with a mild soap solution and rinse 

with water.  Check O-rings and lubricate with water soluble lubricant. 

KY Jelly

®

 or other water based lubricants may be used.  Petroleum 

based lubricants (such as Vaseline

®

must not be used.

Step 5

Before re-installing the filter bowls back on to the system, check 

O-rings to make sure they are still in place. *

Caution:

Insert a new sediment filter (cloth like appearance) into the 1st Stage 

filter housing which is the one on the water inlet side (green tube from 

the adapt-a-valve) of the RO system and re-install housing.

Step 6

Insert the new Carbon Block filter (White end caps & plastic netting) 

into the second filter housing and re-install housing.    

Step 7

Step 8 

Turn water supply on to the unit at the adapt-a-valve.

Open the RO faucet and leave it open until water begins to trickle out 

(it will come out slowly).

Step 10

Step 9

Close the RO faucet allowing the storage tank to fill with water.  It may take 3 to 6 hours to 

fill the tank completely depending on the production capability of the membrane, local water 

temperature and water pressure. 

*

O-ring

Open

Close

ON

OFF

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING

Summary of Contents for GTS350C

Page 1: ...ng Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Under the counter Reverse Osmosi...

Page 2: ...ecommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appear...

Page 3: ...ect Fittings on Your RO System 7 Mount the Reverse Osmosis Faucet 8 Drain Saddle Installation 8 Red Tube Connection Drain Saddle 8 Green Tube Connection Feed Water 8 Blue Tube Connection RO System 9 T...

Page 4: ...0 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness...

Page 5: ...YELLOW TUBE BALL VALVE CHECK VALVE ELBOW FLOW RESTRICTOR ELBOW WHITE TUBE WHITE TUBE WHITE TUBE BLUE TUBE 1 4 DRAIN SADDLE RO FAUCET Pre Filter sediment FPMB5 978 Housing Lid FH4200WW14 Pre Filter car...

Page 6: ...e porcelain to crack or chip Using a 1 diamond tip hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool durin...

Page 7: ...nect ensure the system is depressurized before removing the tube Push in the col lect squarely against face of fitting With the collet held in this position the tube can be removed The fitting can the...

Page 8: ...you may use a small screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both...

Page 9: ...to the Tee fitting attached to blue and white tubes slip the yellow tube through the white compression nut hand tighten the white nut and add 1 4 turn with a wrench Refer to diagram on page 5 Compres...

Page 10: ...fourth tank can be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming c...

Page 11: ...ith water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re in...

Page 12: ...et and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system at the adapt a valve Keep the RO faucet open...

Page 13: ...embrane when TDS reduction falls below 75 Step 1 Turn off the incoming water supply to the RO at the adapt a valve Open the RO Faucet and allow water to drain from the tank until it is completely empt...

Page 14: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Page 15: ...ssure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tube and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain lines Cle...

Page 16: ...ere is an average of 4 gallons of reject water for every 1 gallon of product water produced REFER TO OWNER S INSTALLATION SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION F...

Page 17: ...valent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If...

Page 18: ...Page 18 Service Record Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2nd stage Carbon 6 months TFM Membrane 2 3 years...

Page 19: ...Page 19...

Page 20: ...nd 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biol...

Reviews: