background image

7

CIVIC1-MOI-IT-W-ML-09-18-Rev.1

Watts Water Technologies, Inc.

EN

Waste disposal of electrical and elec-

tronic equipment (WEEE): pursuant to 

Italian Legislative Decree no. 49 of 14 

March 2014, implementing Directive 

2012/19/EU on waste electrical and 

electronic equipment (WEEE). 
The crossed-out wheeled bin symbol 

indicates that the product must be 

collected separately from other waste 

at the end of its useful life. 
The user must deliver equipment at the end of its useful life to 

the designated separate collection facilities for electrical and 

electronic equipment. Proper separate collection of disused 

WEEE to be sent for recycling, treatment and environmentally 

sound disposal helps to avoid possible negative effects on 

the environment and on health and facilitates recycling of the  

materials that make up the equipment. 
For the management of the recovery and disposal of household 

appliances, Watts Industries Italia srl is a member of the Italian 

consortium for recycling small household appliances (Consorzio 

Nazionale Riciclo Piccoli Elettrodomestici - EcoPED). 
Illegal disposal of the product by the user is punishable by 

administrative penalties under applicable legislation.

The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out any technical 

and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer’s assent to Watts terms and conditions found on its  

website at www.wattsindustries.com. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form, unless agreed to in a writing  

signed by an officer of Watts. 

Guarantee

Watts products are thoroughly tested. The said guarantee covers solely replacement or – at the full sole discretion of WATTS - repair, free of charge, of those components of the goods supplied which 
in the sole view of Watts present proven manufacturing defects. The period of limitation for claims based on defects and defects in title is two years from delivery/the passage of risk. This warranty 
excludes any damage due to normal product usage or friction and does not include any modified or unauthorized repair for which Watts will not accept any request for damage (either direct or indirect) 
compensation (for full details see our website). All sales subject to the Watts terms to be found on www.wattsindustries.com 

Installation data

Installation data

Installer’s stamp

Control unit installation date:

Detector replacement date:

RESET

TEST

CIVIC1

105

33

48

58

45 62 90

66

45

90

N1

 - CIVIC1 control unit

B1 -

 UR13 or UR20S detector

Y1 -

 NA gas solenoid valve (Vaux: 24÷230Vac)

L1 -

 Failure alert device (12 V/300 mA max)

Overall dimensions

Vaux

12 Vac/dc

Vaux

12 Vac/dc

N1

B1

L1

Y1

NO  NC

UR20S

UR13

C S A

C S A

+

-

+

-

Alarm

-1

2..

.24

V

+

4...

20m

A

+

12..

.24

V

CIVIC1

Connection diagrams

Control unit with NA solenoid valve, negative mode.

CIVIC1 control unit

UR13 (or UR20S) detectors

UR.20.S detectors 

Depending on model (see dedicated technical data sheet).

Summary of Contents for CIVIC1

Page 1: ...WattsWater eu CIVIC1 Gas detection control Installation manual Installation and Operation Manual Manuale di Installazione e Uso UK IT ...

Page 2: ...g Operation Gas Alarm Environmental compatibility and disposal Troubleshooting Terminal Board Connection diagrams Dimensions Indice Generale Caratteristiche tecniche Installazione Messa in servizio Funzionamento Allarme gas Compatibilità ambientale e smaltimento Analisi dei guasti Morsettiera Schemi di collegamento Ingombri ...

Page 3: ...300mA max Output connections 3 terminals of 2 5 mm2 for C NC NO relay 2 terminals of 2 5 mm2 for open Visual alarms 1 green LED power on 1 yellow LED general abnormality 1 red LEDs gas alarm Audible alarms 1 buzzer noise level 60db at 1m Reset Test button 1 for alarm Reset and detector Test Enclosure RAL7035 grey self extinguishing plastic house Dimensions and weight 158x90x58 mm 6 modules to stan...

Page 4: ...perate incorrectly Ensure compliance with all current electric standards CIVIC1 control unit The control unit must be powered at 12 Vac dc use trans formers with double insulation sized for uninterrupted use for the power utilised See Technical specifications For connecting the relay output use wires with a minimum diameter of 1 5 mm2 Prepare wiring connections according to the electrical diagrams...

Page 5: ...rgised Failure output On Off Interface Positive logic Negative logic Gas alarm LED Red Off On Alarm buzzer Continuous sound Continuous sound Alarm relay De energised Energised permanently or pulsed depending on E2 Failure output Off On Interface Positive logic Negative logic Detector Failure LED Yellow Off On Alarm buzzer Intermittent sound Intermittent sound Failure output Off On Detector failure...

Page 6: ...return used products or to ask for information on environmental compatibility and waste disposal the product packaging can be reused Keep it for future use or to return the product to the supplier Problem Possible cause NC valve does not open Valve not connected Alarm in progress Detector warm up phase in progress Defective detector Presence of failure NO valve does not close Valve not connected C...

Page 7: ... and contracts for sale are expressly conditioned on the buyer s assent to Watts terms and conditions found on its website at www wattsindustries com Watts hereby objects to any term different from or additional to Watts terms contained in any buyer communication in any form unless agreed to in a writing signed by an officer of Watts Guarantee Watts products are thoroughly tested The said guarante...

Page 8: ...nomalia n 1 open collector 12Vdc 300mA max Collegamenti uscite n 3 morsetti of 2 5 mm2 per relé C NC NO n 2 morsetti of 2 5 mm2 per open collector Segnalazioni luminose 1 LED verde alimentazione presente 1 LED giallo anomalia 1 LED rosso allarme gas Segnalazioni acustiche 1 cicalino di intensità sonora 60db a 1m Pulsante Reset Test 1 per Reset allarmi e Test sonda Contenitore Materiale plastico gr...

Page 9: ...care per nessun motivo l elemento sensibile ed i circuiti elettronici Ogni manomissione può com promettere il corretto funzionamento del sistema Assicurarsi di rispettare tutte le normative elettriche vigenti Centrale CIVIC1 La centrale deve essere alimentata a 12 Vac dc utilizzare trasformatori a doppio isolamento dimensionati per un utilizzo continuativo per la potenza impegnata Vedi Dati Tecnic...

Page 10: ...il relativo pulsante per circa 6 secondi Testare le altre sonde ripetendo le operazioni descritte in precedenza Attenzione L utilizzo ripetuto o in concentrazioni elevate di sostanze interferenti alcool gas di accendini etc può provocare il danneggiamento permanente del sensore ed il fuori servizio dell apparecchio Test di anomalia sonde Simulare un anomalia della sonda nel modo seguente scollegar...

Page 11: ...nze può accelerare il normale processo di ossidazione dell elemento sensibile con conseguente diminuzione del tempo di vita Allarme gas In caso di allarme per fuga di gas o di presenza di monossido di carbonio procedere come segue spegnere le fiamme libere e tutti gli apparecchi a gas per nessun motivo accendere o spegnere luci o qualsiasi apparecchio elettrico aprire porte e finestre per ventilar...

Page 12: ...ra Per la gestione del recupero e dello smalti mento delle apparecchiature Watts Industries Italia srl aderisce al consorzio EcoPED Consorzio Nazionale Riciclo Piccoli Elettrodomestici Lo smaltimento abusivo del prodotto da parte dell utente comporta l applicazione di sanzioni amministrative previste dalla normativa vigente Le descrizioni e le fotografie contenute nel presente documento si intendo...