6
Equipment Specifications
SYSTEM MODEL NO. BB-S101
Minimum/Maximum Operating Temperature*
34 to 125°F / 1 to 52°C (125°F / 52°C at 80psi Maximum Pressure)
Minimum/Maximum Operating Pressure*
25psi to 125psi / 172 kPa to 861 kPa
Maximum Continuous Flow Rate for Lead & PFOA/PFOS Reduction**
4 GPM (15 lpm)
Maximum Flow Rate for Chlorine Reduction***
13 GPM (49.2. lpm)
Maximum Flow Rate for Chloramine Reduction***
7 GPM (26.4 lpm)
Inlet and Outlet Connection Size/Type
1" NPT
Unfiltered Water Housing Drain Port Connection Size/Type
½" FNPT
Filter Housing Body Material
Glass Reinforced Polypropylene
Inlet Pressure Gauge Port
1
⁄
4
" FNPT Brass Reinforced
Inlet Pressure Gauge Included
Yes
Swing Bolts (Lid) Material
304 Stainless Steel
O-ring (Lid) Material
EPDM
O-ring (Plumbing Adaptors) Material
EPDM
Nominal Micron Rating
0.5 Micron Nominal
Filter Housing Anchor Kit Included
Yes-
3
⁄
8
" Concrete Anchors (X3)
Number of Filter Cartridges
1
Filter Cartridge Media Type
Lead Adsorption Carbon Block
Filter Cartridge End Cap Material/Color
Glass Reinforced Polypropylene/Green
Filter Cartridge Top Endcap Includes Handle
Yes
Filter Cartridge O-ring (Dual) Material
EPDM
Maximum Allowable Filter Cartridge Pressure Drop
40psi Drop
Flow Monitor Display Type
Color Touch Screen- % Filter Life Consumed / % Filter Life Remaining / Volume Remaining
Flow Monitor Capacity
84,480 Gallons / 319791 Liters (Resettable / Non Programmable)
Positive Indication of Flow
Yes- Flow Wave Icon On Display
BB-M101 Alarm Set Points
Visual Text/Email/on Screen: User Selected @ 50%/90%/95% Filter Life Consumed /
@ 100% Mandatory
Flow Monitor Power Supply
115 VAC / 60Hz
No Wi-Fi Connectivity Alarm
Yes- Visual Alarm Icon on Display Screen
Flow Meter Type
Inline Flow Through Turbine Meter
Flow Meter Connection Size/Type
1" x 1" MNPT
Flow Meter Body Material
Glass Reinforced Polymer
* Minimum and Maximum Operating Temperatures and Pressures listed above apply to complete system as well as all individual components including filter
housing, filter cartridge and volumetric flow monitor/meter.
** See Certified Substance Reduction for specific flow and reduction claims.
*** Claims are not performance tested or certified by IAPMO. Performance claims are based on independent laboratory and manufacturer’s internal test data.
Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary. See Certified Substance Reduction for
certified chlorine flow and reduction claims.
Flow Rate and Pressure Drop
Low Pressure Drop
The Watts BB-S101 system uses
a large, high capacity carbon block
filter cartridge to ensure the highest
degree of performance while offer-
ing the highest possible flow rate at
the lowest possible pressure drop.
Pressure drop testing conducted
at Watts’ Peoria, AZ facility using
approximately 73ºF water. Test
results reflect new filter cartridge
flow rate and pressure drop
performance.
0
5
10
15
20
25
30
1
2
3
4
5
6
7
8
9
10
11
12
Pressure Drop (psi)
Flow Rate (GPM)
Flow Rate and Pressure Drop