background image

5

IOM-A-Deringer 20G/20GX/30G/30GX_6-8

 

   2005 

EDP#2916000

 

© 2020 Watts

Maintenance of First Dual-action Check Module (continued)

NOTICE

Maintenance of Second Dual-action Check Module

1.   Use a #2 phillips head screwdriver to remove tower screws 

(A) from the second check seat (B). The double torsion 

spring (C) is captured and does not need to be retained  

during maintenance.

2.   After removing the tower screws (A) examine the elastomer 

disk (D) and check seat (E) for fouling or damage.

3.   Should elastomer disk (D) need replacement unscrew disk 

retainer screws (F) and remove disk retainer (G). Carefully 

remove and replace elastomer disk (D). When replacing  

elastomer disk (D) be certain that no air, water or debris is 

trapped in the clapper (H) cavity behind the elastomer disk (D). 

4.   Reverse the order of the above instructions to reassemble check.
 

•   Elastomer disk must be flat in clapper (H) cavity before 

tightening disk retainer screws (F).

 

•   Do not cross thread disk retaining screws (F).

F

G

D

H

B

C

A

E

D

Maintenance of Second Dual-action Check Module

NOTICE

First Check Tower Bosses and Spring Arms Face Up

Orient seat protrusions as shown

Tower Bosses

Spring Arms

The diagram on the right shows the correct orientation of the 
first dual-action check module when being re-attached to the 
seat. In order to maintain the performance of the valve pay 
attention to the proper orientation of the check module. 

Second Check Tower Bosses and Spring Arms Face Down

Orient seat protrusions as shown

Tower Bosses

Spring Arms

The diagram on the right shows the correct orientation of the 
second dual-action check module when being re-attached to 
the seat. In order to maintain the performance of the valve pay 
attention to the proper orientation of the check module. 

Summary of Contents for AMES Deringer 20G

Page 1: ...equired to consult the local building and plumbing codes prior to installation If the information in this manual is not consistent with local building or plumbing codes the local codes should be follo...

Page 2: ...tenance NOTE valve is still under pressure When opening test cocks water will be released Take precautions to ensure discharging water does not damage the surrounding area equipment or create an unsaf...

Page 3: ...first check module flange C gently push the first check module in the downstream direction until the first check module can easily be removed from the access port by hand A A 1 Use a 11 8 socket wrenc...

Page 4: ...A 2 Remove disk retaining washer B 3 Use a flathead screwdriver to remove the gasket from poppet cavity C 4 Install new red silicone poppet disk D 5 Reverse the order of the above instructions to rea...

Page 5: ...the order of the above instructions to reassemble check Elastomer disk must be flat in clapper H cavity before tightening disk retainer screws F Do not cross thread disk retaining screws F F G D H B C...

Page 6: ...t bind against check seat Binding retainer screws against check seat will result in permanent damage to second check modules WARNING FLOW C E A B Not Binding Binding I Installing First Dual action Che...

Page 7: ...g from one side of the valve to the other A B F C E G D Close Test Cocks and Double Check All Closing Sealing Mechanisms 1 Using the test cock wrench or a small adjustable wrench close main test cocks...

Page 8: ...st of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign mater...

Reviews: