background image

RP/IS-909S

For field testing procedure, send for IS-TK-DP/DL, 

IS-TK-9A, IS-TK-99E and IS-TK-99D.
For troubleshooting guide, send for S-TSG.
For other repair kits and service parts, send for  

PL-RP-BPD.
For technical assistance, contact your local Watts 

representative on back page.

Series 909

Reduced Pressure 

Zone Backflow Preventers
Sizes: 

3

/

4

" – 2" (20 – 50mm)

• Installation 
• Service
• Repair Kits 
• Maintenance

No. 909QT-S 1

1

2

" shown

IMPORTANT:

 Inquire with governing authorities for local instal-

lation requirements.

NOTE:

 For Australia and New Zealand, line strainers should be 

installed between the upstream shutoff valve and the inlet of 

the backflow preventer.

Its important that this device be tested periodically in 

compliance with local codes, but at least once per year 

or more as service conditions warrant. If installed on a 

fire sprinkler system, all mechanical checks, such as 

alarm checks and backflow preventers, should be flow 

tested and inspected internally in accordance with NFPA 

13 and NFPA 25.

Limited Warranty:

 Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of 

original shipment.  In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.  THE COMPANY MAKES NO OTHER 

WARRANTIES, EXPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, 

special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs 

resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company 

has no control.  This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above 

limitations may not apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to 

determine your rights.  

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Summary of Contents for 909 Series

Page 1: ...E COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT...

Page 2: ...ofthereliefvalveispositionedbelowthe first check This unique feature allows the valve to be installed either vertically or horizontally 7 Installation procedures must comply with all state and local c...

Page 3: ...d in an accessible location to facilitate testing and servicing A discharge line should be piped from the air gap at the relief valve connection making sure there is adequate drainage Never pipe the d...

Page 4: ...No 2 Step 2 Close test cock No 4 Disconnect bypass hose yellow at test cock No 4 Step 3 Open needle valve B low blue and C bypass yellow bleeding to atmosphere then closing needle valve B blue restor...

Page 5: ...el Seat Second Check Kits 0887121 RK 909 CK2 3 4 1 20 25 0887134 RK 909 CK2 11 4 2 32 50 0887123 RK 909 CK2SS 3 4 1 20 25 0887136 RK 909 CK2SS 11 4 2 32 50 Kit includes Disc assembly Spring Seat Seat...

Page 6: ...4 1 20 25 0887371 RK 909 SV 11 4 2 32 50 Kit includes Seat Seat o ring Piston o ring and lubricant Note 11 4 2 32 50mm 909 909M1 share a common kit To Prevent Shaft Damage Assemble As Shown Caution If...

Page 7: ...s not resolve problem disassemble valve and clean or replace the first check B 2 Clean or replace the relief valve seat B 3 Clean grease or replace the piston O ring B 4 Eliminate source of excessive...

Page 8: ...eb site at www watts com RP IS 909S 1111 EDP 0834246 2011 Watts USA No Andover MA Tel 978 688 1811 Fax 978 794 1848 www watts com Canada Burlington ON Tel 905 332 4090 Fax 905 332 7068 www wattscanada...

Reviews: