REV. 01 - OCTOBER 2020 - BLÜCHER
®
CONNECTED ROOF
17
7.3 Relay
The relay functionality is parametrized in the Config file.
Relay modes
OFF
Default mode
Alarm roof
Blocked drain, Blocked sensor
Alarm Monitor
Low battery, Lost connection, Internal leak
Alarm Roof
and Monitor
Blocked drain, Blocked sensor, Low battery, Lost connection,
Internal leak
Temp One setpoint
For application where only one setpoint is needed
Temp Two setpoints
For application where two setpoints are needed
For more info on Alarm’s, see chapter 7.5 diagnostics
The parameters for the Temp modes, can be parametrized in the config file, see Appendix 13.
Appending on the application, 1 or 2 set points can be selected, see below.
Hysteresis = 1C°
Setpoint 1= 4 C°
Hysteresis = 1C°
Setpoint 1= 4 C°
Setpoint 2 =2 C°