![Watts 900.000.400 User Manual & Installation Manual Download Page 16](http://html.mh-extra.com/html/watts/900-000-400/900-000-400_user-manual-and-installation-manual_876924016.webp)
16
BLÜCHER
®
CONNECTED ROOF - REV. 01 - OCTOBER 2020
7.1.3 Display information
XXX
Symbol Description
Monitor ID
XXXXX
Unique ID on the Monitor, must be set-up in configuration file
Test mode
When symbol is visible, Monitor is in Test mode.
Relay status
When lines are unconnected, relay is OFF
When lines are connected, relay is ON
Monitor
battery level
<5% (6 months) - Plan Monitor change for the near future
<20% (2 years)
<50% (5 years)
<100% (10 years)
Signal
strength
Signal too weak and will cause intermittent operation.
Low signal. Distance/obstructions on the limit.
High signal
Temperature
XX°C
Celsius degrees °C
Water level
X/5
Level 1-5
Alarm
YES/NO IF YES, alarm will be shown in the alarm list.
Version
X.XX
Monitor software version
7.2
Info button
The info button is used for performing several actions. See table below.
Next menu
Short push
Clear alarm
(Alarm list on display) Hold for 2 seconds
Remove SD card
Hold for 5 seconds
Reboot Gateway
Hold for 9 seconds