Page 9
Hot Supply
Cold Supply
Adapta Valve Installation - Part# 134007
Turn off the cold water supply to the faucet by turning the angle stop valve
completely off.
Step 14
Step 15
Attach adapta valve as illustrated in the photos above, choosing the confi guration that fi ts
your plumbing. (When attaching the adapta valve to straight pipe threads, use tefl on tape on
the treads.)
Caution:
Water supply line to the system must be from the cold water supply line only. Hot water
will severely damage your system.
Confi guration for 3/8” compression fi ttings
Confi guration for 1/2” compression fi ttings
Green Tube Connection (From RO Module to The Adapta Valve)
The green tubing may be removed from the quick connect fi tting on the RO Module to ease
with the installation of the Adapta Valve to the supply line (see page 11 for quick connect
fi tting use directions). Make sure to re-attach the green tube to the RO Module after the
Adapta Valve has been installed.
Remove a brass nut, plastic sleeve and brass insert from the
parts bag. Place nut on the green tube (coming from the RO
Module) fi rst, then the plastic sleeve (small taper end of plastic
sleeve must point to the end of tube) and then insert the brass
insert into the end of the tube.
Insert the green tube into the ¼” opening on the Adapta Valve
(supplied in the parts bag) until it stops. Slide nut and sleeve
down and thread onto the male pipe threads. Use a ½” wrench
to securely tighten.
Step 11
Step 13
Step 12
Adapta Valve - Part# 134007
Reverse Osmosis Module Mounting
Step 16
Determine best location for the RO module to be mounted to allow
for future system maintenance. The parts bag has 2 self tapping
screws. Using a phillips screwdriver, screw them into the cabinet
wall using the mounting bracket as a guide.
Do not cut any RO system tubes at this time
Note:
Note:
If the green tubing was removed from the quick connect fi tting on the RO Module in Step
13, re-attach it to the RO Module now (see page 11 for quick connect fi tting use directions).