background image

Page 18

 

 

 
 
 
 

 

 

 

 

 
 
 

 
 

 

Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water 
has no color, taste or odor. It must be measured by an arsenic test kit or lab test.

Public water utilities must have their water tested for arsenic. You can obtain the results from your 
water utility contained with in your consumer confi dence report. If you have your own well, you 
will need to have the water evaluated. The local health department or the state environmental 
health agency can provide a list of test kits or certifi ed labs.

There are two forms of arsenic: pentavalent arsenic (also called As (V), As (+5)) and trivalent 
arsenic (also called As (III), As (+3)). In well water, arsenic may be pentavalent, trivalent, or a 
combination of both. Although both forms of arsenic are potentially hazardous to your health, 
trivalent arsenic is considered more harmful than pentavalent arsenic. 

RO systems are very effective at removing pentavalent arsenic. A free chlorine residual will 
rapidly convert trivalent arsenic to pentavalent arsenic. Other water treatment chemicals such 
as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic. 
A combined chlorine residual (also called chloramine) where it does convert trivalent arsenic to 
pentavalent arsenic, may not convert all the trivalent arsenic in to pentavalent arsenic. If you get 
your water from a public water utility, contact the utility to fi nd out if free chlorine or combined 
chlorine is used in the water system.

This Watts Premier reverse osmosis system is designed to remove up to 98% of pentavalent 
arsenic. It will not convert trivalent arsenic to pentavalent arsenic. Under laboratory standard 
testing conditions, this system reduced 0.30 mg/L (ppm) pentavalent arsenic to under 0.010 
mg/L (ppm) (the USEPA standard for drinking water). Actual performance of the system may 
vary depending on specifi c water quality conditions at the consumer’s installation.  In addition to 
the independent laboratory standard testing conditions Watts Premier has conducted additional 
fi eld testing on our reverse osmosis units to determine trivalent arsenic reduction capabilities. 
Based upon Watts Premier fi eld testing, it has been determined that the RO units are capable 
of reducing up to 67% of trivalent arsenic from the drinking water.  

The RO membrane component of this Watts Premier reverse osmosis system must be maintained 
according to its recommended maintenance cycle. Specifi c component identifi cation and ordering 
information can be found in the installation/operation manual maintenance section, by phone at 
1-800-752-5581 or online www.wattspremier.com

California Proposition 65 Warning
WARNING: this product contains chemicals known to the State of California to cause cancer 
and birth defects or other reproductive harm.  (Installer: California law requires that this warning 
be given to the consumer).  For more information:  www.watts.com/prop65.

Arsenic Fact Sheet

Summary of Contents for RO-PURE

Page 1: ...for future reference Warning Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure and possible damage to property Manual Edition 08 21 07 P N 199404 Model RO PURE System Tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance ...

Page 2: ...urchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 6 months Model Number __________ Serial Number ___________ ...

Page 3: ...fety of your personal information Watts Premier collects personal information when you register with Watts Premier This information is stored in our data base and we do not rent sell or share personal information with other people or nonaffiliated companies We reserve the right to send you certain types of communications such as direct mail email or by telephone relating to our products or product...

Page 4: ...of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 Carbon filter recommended change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membran...

Page 5: ...Faucet in a Porcelain Sink 7 Punch a Hole for the Faucet in a Stainless Steel Sink 7 Watts Chrome Monitor Non Monitored Faucet Installation 8 Green Tube Connection From RO Module To The Adapta Valve 9 Adapta Valve Installation 9 Reverse Osmosis Module Mounting 9 Drain Saddle Installation 10 Tank Ball Valve Installation 10 How To Use Quick Connect Fittings For Tubing Connections 11 Blue Tube Connec...

Page 6: ...iver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 1 4 3 8 Drill Bits Contents of Reverse Osmosis RO System Operating Temperatures Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 85 psi 7 43 g cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5NTU Note Reverse Osmosis water should not be...

Page 7: ...arp edges with a file Step 1 Step 2 Drill a Hole for the Faucet in a Porcelain Sink Most sinks are predrilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer or soap dispenser you will need an additional hole for the faucet Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Premier accepts no res...

Page 8: ...both the red and green lights will flash to indicate that both lights are functional Thereafter it will flash green only when the faucet handle is turned to the ON position When your system is ready to be serviced approximately six months you will see the light flash red when the handle is turned to the ON position Refer to the Six Month Maintenance page 14 section of this manual for filter replac...

Page 9: ...the RO Module after the Adapta Valve has been installed Remove a brass nut plastic sleeve and brass insert from the parts bag Place nut on the green tube coming from the RO Module first then the plastic sleeve small taper end of plastic sleeve must point to the end of tube and then insert the brass insert into the end of the tube Insert the green tube into the opening on the Adapta Valve supplied ...

Page 10: ...either above the disposal or if a second sink drain is available install it above the cross bar on the second sink Installation of the drain line near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Watts offers drain line installation kits that can be used with garbage disposals part numbers 164014 and 164020 Assemble the drain saddle around...

Page 11: ...burrs and sharp edges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the sy...

Page 12: ...saddle and tighten the black nut securely This is a gravity fed line if there is any dip or kink in the tube the rinse water will not flow into the drain properly Water will back up and come out the air gap hole in the back of the faucet base The tubing must be as SHORT and STRAIGHT as possible making a downward slope from faucet to drain saddle to allow for proper drainage Step 26 Note Note Step ...

Page 13: ...rature and pressure After the tank has filled open the RO An optional ice maker kit not included may be purchased from Watts Premier by calling 1 800 752 5582 or buy on line at www wattspremier com If system is connected to an ice maker turn the ice maker off or do not allow water to flow to the ice maker until Step 3 flushing is complete and the tank has been allowed to completely fill Connection...

Page 14: ...mbranes have a life expectancy of between 2 and 5 years depending on the incoming water conditions and the amount of use of the RO system Normally a membrane would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane A water sample may be...

Page 15: ... 4 Filter Cartridges 2 125089 FITTING ELBOW 90 QC 1 4TX1 4I 3 622036 FLOW RESTRICT 550 STAND ALONE 4 134003 VALVE SHUT OFF 1 4 Q C RES 5 119007 TANK 3 GALLON METAL WHITE 7 134007 ADAPTA VALVE 8 116074 FAUCET AG WATTS CHROME MONITOR 9 134018 VALVE BALL ELB 1 4QCX1 4F The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids ...

Page 16: ...be clogged Caused from dishwasher or garbage disposal Disconnect the 3 8 black line at the drain clean the 3 8 black line out with a wire then reconnect Blowing air through the line will not always remove the clog 5 Small amount of water in System starting up Normally it takes 6 10 hours to fill tank Note low storage tank incoming water pressure and or temperature can drastically reduce production...

Page 17: ...7 24 50psi 4 3 27 0 10 10 0 Nitrite 3 1 0 41 86 0 7 24 50psi 0 46 3 0 10 1 0 Nitrate Nitrite 30 4 2 86 0 7 24 50psi 4 8 30 0 10 10 0 Perchlorate 0 14 0 003 97 0 7 39 50psi 0 005 mg L 0 10 10 0 006 Radium 226 228 25pCi L 5pCi L 80 0 7 24 50psi 5pCi L 25pCiL 10 5pCiL Selenium 94 85 0 2 97 0 7 24 50psi 0 2 0 10 10 0 05 TDS 741 22 97 0 7 28 50psi 26 0 750 40mg L 187 Recovery 15 77 Daily Production Rat...

Page 18: ... from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water system This Watts Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic Under laboratory standard testing conditions this system reduced 0 30 mg L ppm pentavalent arsenic to under 0 010 mg...

Page 19: ...t that turns red to notify you for filter replacement Part No 116000 Chrome Non Monitored 49 95 each 116072 Brushed Nickel Non Monitored 59 95 each 116074 Chrome Monitored 69 95 each Watts Premier Hot Water Recirculation Pump Bring convenience and saving to your home giving you hot water instantly at every faucet when you need it This unique product is easy to install and not only provides you wit...

Page 20: ...pres sure which may exceed readings during the day High pressure readings may indicate the need for pressure regulator to prevent damage to appliances Part No 261003 14 95 each Whole House Filter Great for sediment problems such as in well water supply or areas where dirt and rust particles are a problem Includes three 50 Micron sediment filters and wrench 3 4 ports Part No 500223 86 95 each Repla...

Page 21: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 Part No 107075 14 95 pk All In One reversible High Flow Filter Deluxe 5 Way Massaging Spray Replacement filter Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 47 50 Part No 107080 18...

Page 22: ...ot be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This warranty does ...

Reviews: