background image

Page 5

  
 
 
 
  

 

 

 

 
 
 

 
 

 

        Part No.  Description

1    115304    FILTER MODULE

2    134003   AUTOMATIC SHUT OFF VALVE

3    119007    STORAGE TANK - 3 GALLONS

4    560080   ADAPT-A-VALVE KIT

5    420102   FAUCET - TMT - BRUSHED NICKEL

6    134018   TANK VALVE - 1/4F X 1/4” QC

7    164056   DRAIN SADDLE - 3/8” QC - KIT

8    119028    TANK STAND

9    142000   1/4” GREEN TUBING WITH 90° BEND - 4FT

10    142001   1/4” BLUE TUBING WITH 90° BEND - 4FT

11    400048   3/8” BLACK TUBING - 3FT X 1

12    142002   1/4” RED TUBING WITH 90° BEND  - 4FT

13    105311    SEDIMENT PRE-FILTER (RED)

14    105351   CARBON PRE-FILTER (YELLOW)

15    105331   REVERSE OSMOSIS MEMBRANE 50GPD (GREEN)

16    105381   VOC CARBON POST FILTER (SILVER)

Plumbing Diagram and Parts List

COLD WATER
ANGLE-STOP

(SUPPLY)

TANK

FAUCET

GREEN- 1/4” TUBE

FEED

1

5

3

RED -  1/4”

 TUBE

BRINE

6

BLUE -  1/4”

 TUBE

FAUCET

BLUE - 1/4” TUBE

TANK

DRAIN

SADDLE

7

2

AUTO SHUT-OFF VALVE

8

9

BLACK -  3/8” TUBE

DRAIN

10

11

12

10

ADAPT

-A-

VALVE

4

13

14

15

16

Summary of Contents for RO-PURE Plus

Page 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Page 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Page 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Page 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Page 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Page 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Page 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Page 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Page 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Page 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Page 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Page 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Page 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Page 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Page 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Page 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Page 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Page 20: ...Page 20 This page intentionally left blank...

Page 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Page 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...