page 40 of 42
The fire goes out or the
stove stops automati-
cally
1.
The pellet tank is empty
2.
No power
3.
Pellets not being fed
4.
Excessive deposit of ashes in the
grate
5.
Intervention probe temperature
safety of the pellet
6.
Cochlea blocked by dirt
7.
The door is not closed properly
or gaskets worn
8.
Pellet inadequate
9.
Low pellet
10.
Chimney or drain clogged with
nests or foreign bodies
11.
Pressure switch cuts
12.
Smoke extraction motor failure
13.
Alarm active
1.
Fill the tank with pellets
2.
Check plug and presence electricity
3.
Fill the tank with pellets
4.
Clean the brazier
5.
Let the stove cool down completely, reset the man-
ual reset and restart the stove. If the problem persists,
contact your authorized service representative
6.
Pull the plug, empty the tank, remove any foreign
objects
7.
Close the door or replace the gaskets with original
8.
Change the type of pellet recommended by the
manufacturer.
Sometimes, depending on the type,
the stage of adjustment of the parameters need
to vary the level relating to the loading of pellets
9.
Increase the level in the parameter for the pel-
let feed. T
o check the flow of fuel from technical
authorized
10.
Eliminate all foreign matter from the chimney Clean
the smoke duct. Perform periodic cleaning.
11. Verify potential smoke duct is blocked and if
the pressure switch is working properly
12. Check and replace the motor if necessary
13. See paragraph alarms
The air fan convention
(ambient air) never
stops
1.
Temperature sensor temperature
control defective or broken
2.
Smoke probe fails
1.
Check the operation of the sensor and replace if
necessary
2.
Replace smoke probe
The stove does not
light.
1.
Lack of electricity
2.
Probe pellets in bulk
3.
Fuse blown
4.
Pressure switch broken (lockout
indicated)
5.
Smoke outlet or duct clogged
1.
Check that the electrical outlet is plugged in and the
power switch to "I"
2.
Lockout by resetting the rear thermostat,
replace
the thermostat
if it happens again
3.
Replace the fuse
4. Replace the pressure
5. Clean the smoke outlet and / or smoke duct
The manufacturer of the stove any liability and will void the warranty terms of the
product for any inconvenience caused by not following the rules described above.
Any work of service center will be borne by the applicant if they are not complied
with these instructions.
Never turn off the heater by removing electricity. Let always complete the
shutdown cycle, otherwise you may damage the structure and have trouble
lighting in the future.
EN
Summary of Contents for MIGNON6
Page 1: ...MANUAL DE INSTRUCCIONES ESTUFAS DE PELLET ES...
Page 4: ......
Page 47: ...43 44 ES...
Page 48: ...43 44 NOTAS ES...
Page 49: ...44 44 NOTAS ES...
Page 50: ...Cod 001120 Date 06 2021 ES NOTAS 45 44...
Page 51: ...44 44...
Page 52: ......
Page 95: ...Cod 001120 Date Mar2021 EN NOTES page 42 of 42...
Page 96: ...Cod 001120 Date 06 2021 NOTES page 43 of 42...
Page 97: ...1 42...