Watt Stopper DT-200 Installation Instructions Manual Download Page 16

WARRANTY INFORMATION

WattStopper warranties its products to be free of defects in materials and 

workmanship for a period of five (5) years. There are no obligations or liabilities 

on the part of WattStopper for consequential damages arising out of or in 

connection with the use or performance of this product or other indirect damages 

with respect to loss of property, revenue, or profit, or cost of removal, installation 

or reinstallation.

ORDERING INFORMATION

Catalog #

Description

DT-200

Dual Technology Occupancy Sensor, Low Voltage  

w/Isolated Relay

DT-205

Dual Technology Occupancy Sensor, Low Voltage

BZ-50, 150

Power Pack: 120/277VAC, 50/60Hz, 225mA with relay  

connected, 20A ballast/incandescent

B347D-P

Power Pack: 347VAC, 60Hz, 150mA. 15A ballast

S120/277/347E-P

Auxiliary Relay Pack:   120/277VAC, 60Hz, 20A Ballast 

347VAC, 60Hz, 15A Ballast

17479r3  9/2014

Please 

Recycle

2800 De La Cruz Boulevard, Santa Clara, CA 95050

800.879.8585 • www.wattstopper

.com

Please 

Recycle

2800 De La Cruz Boulevard, Santa Clara, CA 95050

800.879.8585 • www.wattstopper

.com

Summary of Contents for DT-200

Page 1: ...g Temperature 32 to 131 F 0 to 55 C Light Level One Step Adjustment 10FC to 200FC Time Delay Adjustment 30 seconds to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 5 sec...

Page 2: ...nutes the lights are switched off A walk through mode can turn lights off after only 3 minutes if no activity is detected after 30 seconds of an occupancy detection The DT 200 operates on 24VDC suppli...

Page 3: ...erage patterns As a general rule each occupant should be able to clearly view the sensor Masking the PIR Lens Opaque adhesive tape is supplied so that sections of the PIR lens can be masked This restr...

Page 4: ...wire on sensor Wire from other side of switch to the red wire on sensor Wiring the Isolated Relay The Isolated Relay is rated for 1A 30VAC VDC Connect the wires necessary to the application that requ...

Page 5: ...osed Contact Orange Normally Open Contact Green Common Isolated Relay Outputs Grey Man Switch DT 200v3 Occupancy Sensor Grey wire on sensor is only used when connecting a manual momentary switch LVSW...

Page 6: ...racket so that it is in line with the half circle notch as illustrated in figure A Push the ball into the Base Bracket opening until it snaps into place being careful not to pinch the wires The bracke...

Page 7: ...htening Screw to hold this position Wall Mount PARALLEL to WALL at 10 foot mounting height Reference Surface Angle Ceiling Mount PARALLEL to VERTICAL at 10 foot mounting height Reference Surface Angle...

Page 8: ...ll not return it to previous settings If Test Mode is enabled after Light Level has been set Light Level functionality will cease to function throughout the duration of Test Mode When Test Mode period...

Page 9: ...or more resets the light to default maximum Press and hold the Light Level button for 5 seconds or until the detection LEDs turn ON and then OFF The LEDs flash rapidly for 10 seconds after the settin...

Page 10: ...re that the Ultrasonic Sensitivity trimpot is set to about 70 clockwise 4 Remain still The red and green LEDs should not flash The lights should turn off after 5 seconds If not see Troubleshooting 5 M...

Page 11: ...od that activates a change from Standby area unoccupied and loads are OFF to Occupied area occupied and loads are ON Both requires detection by PIR and Ultrasonic Either requires detection by only one...

Page 12: ...manual switch and it stays on according to the occupancy logic setting The time delay operates as programmed When the load turns OFF due to lack of occupancy detection it can be turned ON again by oc...

Page 13: ...h voltage is present replace the power pack Red LED does not flash 1 When power is initially applied to the sensor there is a warm up period of 30 to 60 seconds before the LED becomes active 2 Make su...

Page 14: ...corrected the sensor will return to normal operation Check the blue wire connection If necessary replace the power pack Lights do not turn off automatically Green LED flashes Reduce ultrasonic sensit...

Page 15: ...sensor to time out If lights turn off the sensor is working properly adjust sensitivity and time delay for the sensor If lights do not turn off check the wiring between the sensor and power pack If w...

Page 16: ...profit or cost of removal installation or reinstallation ORDERING INFORMATION Catalog Description DT 200 Dual Technology Occupancy Sensor Low Voltage w Isolated Relay DT 205 Dual Technology Occupancy...