Green (Solid): 

All sites/IP Addresses are communicating with the WattBox 

Green (Flashing): 

At least 1 (not all) Sites/IP Addresses are communicating with the 

WattBox 

Red (Solid): 

None of the Sites/IP Addresses are communicating with the WattBox. 

 

When Illuminated: 

Auto Reboot is Enabled, WattBox will perform power cycle for outlets that 

are ON when communication with the assigned Website/IP Address is lost.  

Note that outlets that are OFF, will not power cycle. 

When Not 

Illuminated: 

Auto Reboot is Disabled, no power cycle will occur when communication 

with the assigned Website/IP Address is lost. 

 

Green (Solid): 

The WattBox is powered on and outlets are protected. 

Off: 

The WattBox is not powered on, or the MOVs have opened removing 

power from the outlets. 

 

Green (Solid): 

WattBox processor is in an operating state and can be accessed via the 

WattBox interface 

Green (Flashing): 

Firmware for the WattBox processor is being updated, during this state 

the WattBox cannot be accessed via the WattBox interface. 

Red (Solid): 

WattBox processor is NOT in an operating state, reset button must be 

pressed to return the WattBox to an operating state. 

 

Green (Solid): 

Incoming AC outlet is grounded. 

Off: 

Incoming AC outlet is not grounded and requires inspection by an 

electrician. 

 

Summary of Contents for WB-400-IPCE-8

Page 1: ...tus Changes WELCOME TO WATTBOX WattBox power products are designed specifically to provide customers with advanced protection for their valuable electronics and Custom Integrators with maximum flexibi...

Page 2: ...Adapters on Pg 5 11 Outlets 1 4 Always On 12 Outlets 5 8 Controlled via IP Interface 13 Power Indicators for Outlets 1 8 Illuminates when power is ON x8 1 for each outlet 14 Detachable power cord outl...

Page 3: ...power cycle for outlets that are ON when communication with the assigned Website IP Address is lost Note that outlets that are OFF will not power cycle When Not Illuminated Auto Reboot is Disabled no...

Page 4: ...a particular installation Attach the brackets to the Wattbox in the position desired Install the Wattbox using supplied hardware Small Bracket Mounting 0 0 Screw Position 90 0 Screw Position 0 0 Scre...

Page 5: ...ion does not allow for this use a wall molly or anchor with the appropriate weight rating for the Wattbox 3 Level the template and mark the wall with the screw locations 4 Secure the Wattbox to the wa...

Page 6: ...attbox can be found on the included CD Rom and the SnapAV website www snapav com Note WattBox must be connected to the network and the router on before applying power to the WattBox Router Internet Su...

Page 7: ...d power lines or any other power circuit Do not touch any power line or power circuit Doing so may cause severe physical injury or possibly death WARNING Liquid Avoiding Electrical Shocks Do not opera...

Page 8: ...set too soon the breaker will prematurely sense power overload and not allow Wattbox to operate If the circuit breaker continues to trip try moving one or more components to another Wattbox Too much c...

Page 9: ...rcuitry Yes Thermal Fuse Yes Outlets Type NEMA 5 15 Number of Outlets 8 IP Controlled 4 EMI RFI Noise Filtration All Outlets 53 dB 1kHz to 1MHz Cable Satellite Circuit Connections Gold Plated F Connec...

Page 10: ...ions relative to its surge protection capability and under all of the circumstances failed to protect your connected equipment THIS POLICY IS SUBJECT TO THE CONDITIONS BELOW 1 PROOF OF PURCHASE REQUIR...

Page 11: ...ne maintenance loss of use of the product costs or expenses arising out of reprogramming or loss of programming and or data shipping charges or fees service calls loss or damage occasioned by fire the...

Page 12: ...121101 0910 2012 Wattbox...

Reviews: