2 EDISON SENIOR RAIL ASSEMBLY INSTRUCTIONS
WARNING - Risk of Fire or Electric Shock. It is possible for this office furnishing system to be connected to more than one source of
supply. Disconnect all sources prior to any servicing. A single circuit shall not be powered by more than one source.
WARNING - Electrical connection between rail segments shall be disconnected prior to removal of a mechanical connection.
WARNING - The system may be supplied by a three phase power system with four individual circuits rated at 20 amps/120 volts max
-
imum, or as permitted by local code.
WARNING - No more than 12 duplex receptacles shall be supplied by one circuit. (12 segments Two Duplex, 6 segments Four Duplex)
WARNING - For commercial use only.
NOTE - Installation must be in accordance with the National Electrical Code and local codes. Electrically interconnected tables need
to be mechanically connected.
The Edison Senior Rail is ETL listed to UL962
WARNINGS
It is recommended to perform as much of the rail assembly upside-down, keeping in mind how many installers are available to flip
the run right-side up once assembled.
General Rail Assembly Notes
If 1 - 2 installers:
flip the first rail segment upside down and
complete steps 1 & 2. Then flip the rail right side up and continue
with instructions, adding one segment at a time for step 3.
If 3+ installers:
complete steps 1-4 with the rail flipped upside
down. Once complete, flip right side up. The length of run will
determine how many installers are needed to perform the flip.