19.2
General settings
To view the general settings menu, select
GENERAL SETTINGS
from the main menu.
Auto restart
This pump offers an auto restart feature. If active on power loss, it restores the pump when power returns to
the operating state it was in when power was lost.
For example, if the pump was running in analog mode prior to power loss, it would return to the same
operating mode and continue to run at a proportional speed to the analog input.
Press
ENABLE
/
DISABLE
to turn the auto restart feature on/off.
Do not use auto restart for more than 20 mains power starts per hour.
We recommend remote control where a high number of starts is
required.
Pump will start automatically if start conditions are met.