6 . 1 4
■
Wa t l o w P o w e r S e r i e s
P a r a m e t e r s , C h a p t e r 6
[dATA]
System Data Manipulation
[`Loc]
Global/Menu Lockouts
[Info]
Unit Information
[diag]
Diagnostics
[`pw]
Factory Password
[CIn1]
Calibrate Analog Input Signal Zone 1*
[CIn2]
Calibrate Analog Input Signal Zone 2*
[CIn3]
Calibrate Analog Input Signal Zone 3*
[C|rtr]
Calibrate Retransmit*
[Fcty]
Factory Page
Go to a factory
menu.
Factory Mode ->
Requires factory
password to access
calibration para-
meters.
Factory Page
To enter the Factory Page, press the Home, Left and Right keys (
± ¬ ®
) together
while in the Setup Page. Each of the following menus in the Factory Page are selected by
pressing the Increment/Decrement keys (
Ó Î
). Each press of the button will scroll you
up or down through these main menu options.
To select a parameter within a menu, use the Left/Right arrow keys (
¬ ®
). The
parameter appears in the bottom display.
To select a value for each parameter (either alpha or numeric), use the
Increment/Decrement keys (
Ó Î
). The value appears in the upper display.
Pressing the Home key (
±
) in this menu will return you to the Display Loop.
The Factory Page contains nine menus.
The Factory Mode parameters of the Factory Page are used for calibration of the Power
Series. Since the Power Series is precalibrated at the factory; field calibration may only be
necessary in the event that field service work is performed. Field calibration procedures
are available at Watlow’s website, http://www.watlow.com/.
*
NOTE: To enter the Factory Mode requires a password. Call Watlow at +1 (507) 454-5300, and ask an
applications engineer for this password. Once the password is entered, the controller is in Factory
Mode. The controller’s power must be cycled to exit the Factory Mode.
Active if retransmit and heater
diagnostics options are installed.
Active if
[`Cfg]
is set to
[Uolt]
.
881 r/w
[1)00]
(1000)
[rt|U_]
to
[1)00]
(Retransmit Output
Low Voltage to 1000)
[rt|U–]
Retransmit Out-
put High Voltage
(Volts)
Select voltage that
will correspond to
[Cur–]
or
[HUA–]
.
Active if retransmit and heater
diagnostics options are installed.
Active if
[`Cfg]
is set to
[Uolt]
.
880 r/w
[```0]
(0)
[`)00]
to
[rt|U–]
(0 to Retransmit Out-
put High Voltage)
[rt|U_]
Retransmit Out-
put Low Voltage
(Volts)
Select voltage that
will correspond to
[Cur–]
or
[HUA–]
.
Display
Parameter
Range
Default
Modbus
Conditions for
Address
Parameters to Appear
read/write