10.4
DFA
The DFA Finisher Interface PCB is the interface between the printer and the
finisher.
The following input and output signals are provided:
Status ouput signals from the PSQ
Control input signals from the
printer
LEDs are
RED
. LED 11, 12 & 13 must be ON to
let the PSQ run online.
LEDs are
GREEN
.
LED11
ST0
LED off = Offline
LED19
C0
Sheet exit
LED12
ST1
LED off = Fault
LED20
C1
End of set
LED13
ST2
LED off = Full
LED21
C2
Cycle up
LED14
ST3
Pulse = sheet delivered
LED22
C3
End of job
LED15
ST4
Pulse = set delivered
Sheet Exit
End of set
Cycle up
End of job