Power and Control
Plockmatic PowerSquare™ 224 - Service Training Workbook
31
10.
Power and Control
10.1
Power
The PSQ uses a single phase power supply. Internally the power supply voltage
is changed to:
• 242V AC for the low voltage power unit and the main drive motor
• 230V AC for the shuttle positioner motor and the bridge motor.
The main drive motor is a 3 phase motor. A frequency inverter is used to change
the single phase to 3 phase.
Refer to the following:
• 7.1 (High Voltage Connections) shows the AC Wiring
Interlock PCB
Terminal block
Low Voltage Power Unit
Fuse / Relay PCB
Tr
Main switch
1 phase to
3 phase
Main drive
Shuttle motor
Bridge motor
242V
230V
28V
5V