background image

Page 26

S

ERVICE

 I

NFORMATION

GENERAL INFORMATION

Your 

HOT SPRING

 spa has been designed to provide years of trouble-

free use. As with any appliance, problems may occasionally occur that 

require the expertise of a qualified service person. Though such simple 

repairs as resetting a GFCI switch or breaker, high limit thermostat, or 

pressure switch, or replacing a light bulb may not require a service call, 

they may indicate that a more serious condition exists. These conditions 

may require an experienced service person. Before calling for service, 

please refer to the Troubleshooting Guide.

NOTE:

 Always retain your original sales receipt for future reference.

GFCI AND HIGH LIMIT THERMOSTAT

If your spa fails to operate at any time, the following items should be 

checked:
1.  Check the power supply to the spa.
2.  Check the GFCI (located at the end of the cord in standard models 

or in the electrical subpanel in 30 amp converted models) and see 

if it has tripped. If a GFCI has tripped, reset it. If it will not reset, 

this may be an indication of a ground fault (short circuit) within the 

electrical components. Contact an Authorized Service Technician for 

a complete diagnosis.

3.  If, upon checking the GFCI you find it has not tripped, check the 

house breaker panel and ensure the main breaker for the electrical 

circuit supplying the spa has not tripped. If it has, this is an indication 

that either the circuit was overloaded or a ground fault exists 

between the breaker panel and the spa receptacle. Contact a 

qualified electrician.

4.  If, upon checking the main house breaker, you find no failures, 

the heater high-limit thermostat should be checked. Tripping of 

the heater high-limit thermostat is normally a result of one or a 

combination of any of these problems: 1) blockage within the system 

plumbing, 2) switch malfunction in the heater circuit, or 3) the low 

speed mode of the jet pump is not functioning. 

5.  If the heater high-limit has tripped, the control panel display will 

display HL. Reset the heater high-limit by allowing the water to cool 

and disconnecting power to the spa for at least thirty seconds. If 

the heater high-limit continues to trip, contact an Authorized Service 

Technician for a complete diagnosis.

If the spa does not function and the GFCI or GFCI breaker and heater 

high-limit have not tripped, then the problem should be referred to an 

Authorized Service Technician. Refer to the Troubleshooting Guide for 

additional service information.

MISCELLANEOUS SERVICE 

INFORMATION

The jet pump is equipped with an overload cut-off switch, which is 

designed to protect the pump from overheating. If the pump shuts itself 

off in a new spa, it is usually the result of one, or a combination of, the 

following factors:

High Temperature:

 During the summer months, especially in warmer 

climates, the ambient temperature contributes to excessively high 

temperatures within the equipment compartment.

Improper House Wiring:

 If the spa is not connected to a dedicated 

circuit, or is connected to an extension cord, or the house wiring is 

undersized, the pump may starve for voltage and therefore may draw 

more amperage and generate excessive heat. This will often cause the 

circuit breaker to trip repeatedly.

IMPORTANT

:

1.  If the pump is shutting down due to excessive heat, make sure the 

equipment compartment has adequate ventilation. The air gap at 

the bottom and the jet pump vent at the bottom left corner must not 

be blocked. Should your jet pump continue to shut off after short 

periods of use, contact a qualified service technician.

2.  The 

HOT SPRING

 spa is equipped with a safety suction spring 

valve which will break the prime of the jet pump if both suction 

fittings are obstructed.

ACTS INVALIDATING WARRANTY

The limited warranty is void if the 

HOT SPRING

  Spa has been 

subjected to alteration, misuse or abuse, or if any repairs on the spa 

are attempted by anyone other than an authorized representative of 

WATKINS WELLNESS

. Alteration is defined as any component or 

plumbing change, electrical conversion, or the addition of any non-

approved sanitation, or water purification device, or heating system 

which contributes to a component failure, unit failure, or unsafe 

operating condition. Misuse and abuse shall include any operation of 

the spa other than in accordance with 

WATKINS WELLNESS

 printed 

instructions, or use of the spa in an application for which it is not 

designed; specifically: use of the spa in a non-residential application; 

damage caused by operation* of the spa at water temperatures outside 

the range of 35°F and 120°F (2°C and 49°C); damage caused by a 

dirty, clogged, or calcified filter cartridge; damage to the spa surface 

caused by the use of Tri-Chloro Chlorine, BCDMH, chemical tablets in a 

floater, acid, or any other spa chemicals, or spa surface cleaners which 

are not recommended by 

WATKINS WELLNESS

; damage caused by 

allowing undissolved spa sanitizing chemicals to lie on the spa surface 

(no spa surface material can withstand this kind of abuse); damage 

to components or spa surface caused by improper water chemistry 

maintenance; and damage to the spa surface caused by leaving the spa 

uncovered while empty of water and in direct exposure to sunlight (this 

may cause solar heating distress in warm weather regions). These are 

considered abuses and may invalidate this warranty.
*Operation of the spa 

DOES NOT

 mean “use” of the spa! 

WATKINS 

WELLNESS

 does not recommend using the spa if the water 

temperature is above or below the spa’s control panel temperature 

range.

DISCLAIMERS

WATKINS WELLNESS

 shall not be liable for loss of use of the 

HOT 

SPRING

 

 

spa or other incidental or consequential costs, expenses, or 

damages, which may include but are not limited to, the removal of a 

permanent deck or other custom fixture. Any implied warranty shall have 

a duration equal to the duration of the applicable warranty stated above. 

Under no circumstances shall 

WATKINS WELLNESS

, or any of its 

representatives, be held liable for injury to any person, or damage to any 

property, however arising.

Service Information

English

French

Spanish

Summary of Contents for HotSpring Hot Spot Relay

Page 1: ...HOT SPOT COLLECTION RELAY RHYTHM PACE STRIDE 2022 OWNER S MANUAL English French Spanish...

Page 2: ...o change specifications or design without notification and without incurring any obligation In most cities and counties permits will be required for the installation of electrical circuits or the cons...

Page 3: ...OSTIC LCD MESSAGE 16 JET MENU RELAY MODEL REL 17 RHYTHM MODEL RHY 18 PACE MODEL PAC 19 STRIDE MODEL STD 20 SPA CARE AND MAINTENANCE DRAIN REFILL INSTRUCTIONS 21 PREVENTION OF FREEZING 21 FILTER SYSTEM...

Page 4: ...cle 810 of the National Electric Code ANSI NFPA70 WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due...

Page 5: ...may cause unconsciousness with the possibility of drowning Persons using medications should consult a physician before using a spa some medication may cause a user to become drowsy while other medica...

Page 6: ...e an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the problem contact your authorized HOT SPRING dealer Many problems can e...

Page 7: ...reating a unique massage pattern 7 The Standard Rotary jet provides a strong unique massage 8 The Standard Directional jet with directional nozzle provides a strong flow of water 9 The PRECISION jet w...

Page 8: ...codes this includes the location of the spa the foundation of the spa as well as the electrical installation of the spa Installation instructions in the form of a Pre Delivery Instruction booklet can...

Page 9: ...se Dial a new ease mineral cartridge to setting 6 and snap into the top space of the cartridge holder Dial ease SmartChlor Cartridge per the setting chart based on your gallons see page 10 IF USING FR...

Page 10: ...equipment compartment door Loosen the union on the top of the pump s to allow the air to escape When water is present hand tighten the union Turn power back on activate the pump and check to make sur...

Page 11: ...ly a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not overdose your spa Handle all containers with...

Page 12: ...bisulfate To raise the pH level use FRESHWATER pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to location and user to user therefore it is important to consul...

Page 13: ...ensure it is empty Discard in trash or recycle Set the blue Mineral Cartridge to 6 hold the bottom and turn the top until 6 appears in the window No further adjustments are necessary for the life of...

Page 14: ...uper Chlorinate Shock the spa to reactivate the silver ion cartridge allow the release of silver ions and quickly destroy any remaining contaminants Without this weekly shock treatment the silver ion...

Page 15: ...assist with the water maintenance draining or winterizing of the spa is recommended Spas equipped with our FRESHWATER III ozone system can extend this to 4 weeks The FRESHWATER III ozone system does n...

Page 16: ...nitric acid a highly corrosive chemical is a byproduct of the ozone generating process Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone Oxidize...

Page 17: ...n a new light mode will appear The sequence is as follows White Red Green Blue Red Purple Yellow Aqua Amber color wheel 1 color wheel 2 The last light mode used will come back on when the light is tur...

Page 18: ...5 seconds to allow the exit timer to expire and store the setting OPERATIONALMODES RELAY RHYTHM ONLY SETTING THE CLOCK Enter the program menu by holding down the Light button for 5 seconds The display...

Page 19: ...lters make sure water valves are open make sure spa has a proper water level If problem persists call your Hot Spring Dealer SETTING ECONOMY MODE In Economy mode you are able to lower the set temperat...

Page 20: ...Jet C 1 XL Rotary Jet D 1 Water feature E 6 PRECISION Jets F 2 PRECISION Jets Jet Pump 2 A 2 PRECISION Jets 2 Standard Rotary Jets and 1 XL Directional Jet B 6 PRECISION Jets C 2 PRECISION Jets 2 Stan...

Page 21: ...Rotary jet B 4 PRECISION Jets and 1 Standard Directional Jet C 2 PRECISION Jets 2 Standard Rotary Jets and 1 XL Directional Jet D 1 Water feature E 2 PRECISION Jets Jet Pump 2 A 6 PRECISION Jets 1 XL...

Page 22: ...Jets 2 Standard Directional Jets and 1 XL Directional Jet E 1 Standard Rotary Jets A B C D E JET SYSTEM 2 A 4 PRECISION Jets and 1 XL Directional Jet B 2 PRECISION Jets 1 Standard Rotary Jet and 1 XL...

Page 23: ...Jet System A 6 PRECISION Jets 1 XL Rotary Jet B 2 PRECISION Jets and 1 Standard Directional Jet and 1 Standard Rotary Jet C 4 PRECISION Jets D 2 PRECISION Jets 2 Standard Directional Jets and 1 XL Dir...

Page 24: ...OTE When warmer weather returns approx 60 70 F 15 5 21 C the insulating kit must be removed to prevent overheating of the jet pump WINTERIZING YOUR SPA If you leave the spa unused for a long period of...

Page 25: ...ich it was removed Do not overtighten WARNING Do not use the spa with the filter cartridge or filter standpipe removed CARE OF THE SPA PILLOWS The spa pillows will provide years of comfort if treated...

Page 26: ...Use any lifting mechanisms chemicals or cleaners except those recommended by WATKINS WELLNESS or itsAuthorized Sales and Service Dealer COVER LIFTER SYSTEM Clearance required behind cover when open C...

Page 27: ...ccordance with the wiring information contained in the electrical control box or on the back of the field wiring access panel of the equipment module 115 VOLT INSTALLATION 20 amp Spas provided with a...

Page 28: ...HM MODELS NOTE The subpanel must be placed within 100 feet 30 m of the main electrical service panel and between 5 feet 1 5 m and 50 feet 15 m away from the spa All electrical connections must be made...

Page 29: ...spa is not connected to a dedicated circuit or is connected to an extension cord or the house wiring is undersized the pump may starve for voltage and therefore may draw more amperage and generate exc...

Page 30: ...reached at 800 999 4688 Extension 8432 Monday through Friday 8 am to 5 pm Pacific Standard Time PST or e mail customerservice watkinsmfg com TROUBLESHOOTING Should you experience any problem whatsoev...

Page 31: ...refilling the spa a jet pump is operating but water is not flowing from any of its jets Pump is not properly primed 1 Turn off power to the spa at the breaker and remove the equipment compartment doo...

Page 32: ...kg 4 150 lbs 1 880 kg 115 lbs ft 565 kg m 115 volt 20 amp dedicate GFCI protected circuit OR 115 volt 30 amp requires 30 amp subpanel GFCI protected circuit OR 230 volt 30 50 amp Single phase GFCI pro...

Page 33: ...MENT 1 Raise Door Panel making sure it goes up behind Spa Shell then lower to rest on Spa Ledge making sure the Door Panel Clips are behind the Spa Clips and the Door Panel has the same spacing on eac...

Page 34: ...English French Spanish...

Page 35: ...English French Spanish...

Page 36: ...PACE MODEL PAC STRIDE MODEL STD 2021 Watkins Wellness All Rights Reserved Hot Spot Relay Rhythm Pace Stride Precision No Fault FreshWater FreshWaterAg Clean Screen and Vanishing Act are trademarks of...

Reviews: