Watex WATEX CMS-8 Installation And Operation Manual Download Page 15

 

WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5

[email protected]

, Tel. +371 67381989, www.watex.eu 

 

15 

START UP 

 

Usually all key operating parameters of the WATEX CMS series filter have already been set at the service center. The only thing 
that is planned to set for the first run is the time setting. 
 

Regeneration cycles and capacity programming 

Press and hold the 

“NEXT”

 button simultaneously and arrow down 

 and hold for 3 seconds. 

1)

 

The word "softening" flashes in the upper left corner.  

2)

 

Press 

"NEXT". 

The first "backwash" and the duration of the cycle appear in minutes. Arrows

 and 

 is possible to 

change the duration of the cycle. 

3)

 

Press 

"NEXT"

 and the second mode "brine" (brine suction) and cycle duration in minutes are displayed. With arrows 

 and 

 it is possible to change the duration of the cycle.  

4)

 

Press 

"NEXT".

  The  second  "backwash"  and  the  duration  of  the  cycle  appear  in  minutes.  Arrows

  and 

  is 

possible to change the duration of the cycle. 

5)

 

Press 

"NEXT"

 ."rinse" and the duration of the cycle appear in minutes. Arrows 

 and 

  it is possible to change 

the duration of the cycle.  

6)

 

Press 

"NEXT"

  and  "fill"  (reagent  tank  refill)  and mode  duration  in  minutes  are  displayed.  Arrows 

  and 

  it  is 

possible to change the duration of the mode. 

7)

 

Press 

"NEXT"

  to  display  the  capacity  of  the  unit  in  cubic  meters.  Use  the  arrows  to  change  the  capacity  of  the 

machine. By pressing 

"NEXT"

 the previously set data is automatically saved and the programming progresses to the 

next settings. Next, press 

"NEXT"

 until the current day is displayed. 

Therefore, the setup cycle is closed and all settings are saved. 

Rinsing mode duration and volume settings 

In some circumstances, there is a need to change the rinse mode duration. To do this, do the following: 

Press and hold simultaneously the button 

“NEXT”

 and the arrow down 

 for 3 seconds. 

 

1)

 

In the upper left corner flashes the word "filtering". 

2)

 

Press 

“NEXT”

 and there will appear the first rinsing mode “backwash’’ and duration of the mode in minutes. Duration 

of the mode can be changed by arrows 

 and 

3)

 

Press 

“NEXT”

 and there will appear the second rinsing mode “brine’’(agent suction in) and duration of the mode in 

minutes. Duration of the mode can be changed by arrows 

 and 

. Press 

“NEXT”

 

Thus, the setting mode is closed and all the settings are saved. 

 

Manual regeneration 

 

Sometimes you need to make regeneration earlier before the system determines that it is necessary; it is usually referred to 

as manual regeneration. It is possible that there was a period when the water has been used more than usual, for example, where 
there have been more visitors or more linen have been washed. 
 

 

To initiate a manual regeneration in the set deferred regeneration time press and release REGEN. Then the display will flash 

the words "REGEN TODAY", indicating that the system will initiate regeneration before the pre-set regeneration. If you have 
pressed the "REGEN" button by mistake, re-pressing the button will cancel the request. 
 

Summary of Contents for WATEX CMS-8

Page 1: ...info watex eu Tel 371 67381989 www watex eu Installation and operation manual WATEX CMS 8 9 10 12 13 14 WATER SOFTENER Read the instructions carefully before use Watch CMS water softener start up vide...

Page 2: ...a Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 2 CONTENTS INTRODUCTION 3 REQUIREMENTS 3 SPECIFICATIONS 4 SYSTEM MAIN COMPONENTS 5 OPERATION MODES 7 INSTALLATION 8 START UP 15 PROBL...

Page 3: ...another person using your hands Moving by hands it is recommended to grab the top behind the control valve housing the place where the control valve connects to the tank and the bottom behind the blue...

Page 4: ...Width m 0 28 0 28 0 28 0 3 0 46 0 46 Height m 1 14 1 47 1 62 1 57 1 62 1 91 Weight filled with water kg 50 60 70 95 155 195 Connection in out drain inches 1 1 3 4 1 1 1 Clack control unit WSCI 1 WS CI...

Page 5: ...atvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 5 SYSTEM MAIN COMPONENTS The softener has three main basic components resin tank Clack control valve and brine tank 2 1 1 Co...

Page 6: ...ufficient to dissolve part of the NaCl regeneration cycle Brine well The brine well is a cylindrical barrier that keeps the salt or potassium chloride away from the safety float and air check valve wh...

Page 7: ...s the resin and large amounts of sodium ions replace the hardness ions accumulated during service 3 Second backwash After brine is completely removed from the brine tank into the resin tank the brine...

Page 8: ...indicating arrows If you look at the filter from the front on the right side is the inflow and on the left side is discharge The filter s connection to the mains outer thread size 1 inch of both input...

Page 9: ...rinsing is not dropping out Secure it Important Make sure the garden hose is not folded because it will reduce rinsing water flow and the filter is likely to have incomplete rinsing which can lead to...

Page 10: ...trol panel is shown in the drawing highlighting the connection point of the reagent supply line The pipeline connection is carried out as follows 1 Unlock the control unit reagent by removing the clam...

Page 11: ...ypass option Directional shut off arrows for flow Normal Bypass Diagnostic mode Shut off mode Radial seals allow side to side and up down minor plumbing misalignments connections need only hand tighte...

Page 12: ...To ensure a continuous supply of electricity from the source located not farther than 2 meters from the water softener Adapter wire must be connected inside the control valve 1 Remove the front cover...

Page 13: ...s made while in programming modes Toggles between available User Display Screens or Allows programmer to advance to the next display screen in programming mode Change variable being displayed in progr...

Page 14: ...WATEX Ltd Latvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 14 Setting Time of Day Installer Display Settings...

Page 15: ...iously set data is automatically saved and the programming progresses to the next settings Next press NEXT until the current day is displayed Therefore the setup cycle is closed and all settings are s...

Page 16: ...peration control During operation the normal user display is time of day current flow rate liters per minute remaining capacity cubic meters per hour Each of these can be viewed by pressing NEXT to sc...

Page 17: ...E3 Motor runs too long out of adjustment trying to reach the next regeneration cycle position 1004 Motor runs too long out of adjustment trying to reach the starting position If some other code shows...

Page 18: ...ntrol valve does not make recovery automatically but it does so when REGEN button is pressed a Water flowing through the bypass a Close the bypass b the meter is disconnected b Connect the meter to th...