Watex WATEX CMS-8 Installation And Operation Manual Download Page 13

 

WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5

[email protected]

, Tel. +371 67381989, www.watex.eu 

 

13 

Button Operation and Functions

 

 
 

  

 

 
 
 
 
 
 

 
Setting Time of Day 
Setting Time of Day 

Allows programmer to set the time of day or to “Escape” out of 
programming and save any changes made while in programming modes  

Toggles between available User Display Screens or 
Allows programmer to advance to the next display screen in programming mode 

Change variable being displayed in programming mode 

Toggles scheduled regen on/off 
Hold for more than 3 seconds to start immediate regen 
Backs up 1 step in programming mode 

By pressing the above buttons in order you can 
Lock (LoC) or to Unlock (UnLoC) someone from 
accessing the OEM setup screens  

 

Summary of Contents for WATEX CMS-8

Page 1: ...info watex eu Tel 371 67381989 www watex eu Installation and operation manual WATEX CMS 8 9 10 12 13 14 WATER SOFTENER Read the instructions carefully before use Watch CMS water softener start up vide...

Page 2: ...a Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 2 CONTENTS INTRODUCTION 3 REQUIREMENTS 3 SPECIFICATIONS 4 SYSTEM MAIN COMPONENTS 5 OPERATION MODES 7 INSTALLATION 8 START UP 15 PROBL...

Page 3: ...another person using your hands Moving by hands it is recommended to grab the top behind the control valve housing the place where the control valve connects to the tank and the bottom behind the blue...

Page 4: ...Width m 0 28 0 28 0 28 0 3 0 46 0 46 Height m 1 14 1 47 1 62 1 57 1 62 1 91 Weight filled with water kg 50 60 70 95 155 195 Connection in out drain inches 1 1 3 4 1 1 1 Clack control unit WSCI 1 WS CI...

Page 5: ...atvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 5 SYSTEM MAIN COMPONENTS The softener has three main basic components resin tank Clack control valve and brine tank 2 1 1 Co...

Page 6: ...ufficient to dissolve part of the NaCl regeneration cycle Brine well The brine well is a cylindrical barrier that keeps the salt or potassium chloride away from the safety float and air check valve wh...

Page 7: ...s the resin and large amounts of sodium ions replace the hardness ions accumulated during service 3 Second backwash After brine is completely removed from the brine tank into the resin tank the brine...

Page 8: ...indicating arrows If you look at the filter from the front on the right side is the inflow and on the left side is discharge The filter s connection to the mains outer thread size 1 inch of both input...

Page 9: ...rinsing is not dropping out Secure it Important Make sure the garden hose is not folded because it will reduce rinsing water flow and the filter is likely to have incomplete rinsing which can lead to...

Page 10: ...trol panel is shown in the drawing highlighting the connection point of the reagent supply line The pipeline connection is carried out as follows 1 Unlock the control unit reagent by removing the clam...

Page 11: ...ypass option Directional shut off arrows for flow Normal Bypass Diagnostic mode Shut off mode Radial seals allow side to side and up down minor plumbing misalignments connections need only hand tighte...

Page 12: ...To ensure a continuous supply of electricity from the source located not farther than 2 meters from the water softener Adapter wire must be connected inside the control valve 1 Remove the front cover...

Page 13: ...s made while in programming modes Toggles between available User Display Screens or Allows programmer to advance to the next display screen in programming mode Change variable being displayed in progr...

Page 14: ...WATEX Ltd Latvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 14 Setting Time of Day Installer Display Settings...

Page 15: ...iously set data is automatically saved and the programming progresses to the next settings Next press NEXT until the current day is displayed Therefore the setup cycle is closed and all settings are s...

Page 16: ...peration control During operation the normal user display is time of day current flow rate liters per minute remaining capacity cubic meters per hour Each of these can be viewed by pressing NEXT to sc...

Page 17: ...E3 Motor runs too long out of adjustment trying to reach the next regeneration cycle position 1004 Motor runs too long out of adjustment trying to reach the starting position If some other code shows...

Page 18: ...ntrol valve does not make recovery automatically but it does so when REGEN button is pressed a Water flowing through the bypass a Close the bypass b the meter is disconnected b Connect the meter to th...