DANGER

Risk of electric shock:

Install the controller at least five (5) feet (1.52m) from the inside wall of the pool and/or spa/hot tub using non-metallic plumbing. Canadian  
installations must be at least three (3) meters from the water. Children should not use spas or hot tubs without adult supervision. Do not use 
spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment. People using medications and/or having an 
adverse medical history should consult a physician before using a spa or hot tub.

WARNING

To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built-in operating and high  
limit controls to limit water temperature for pool/spa applications. This device should not be relied upon as a safety limit control.

WARNING

•  People with infectious diseases should not use a spa or hot tub.

•  To avoid injury, exercise care when entering or exiting the spa or hot tub.

•  Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.

•  Before entering a spa or hot tub, measure the water temperature with an accurate thermometer.

•  Do not use a spa or hot tub immediately following strenuous exercise.

•  Prolonged immersion in a spa or hot tub may be injurious to your health.

•  Do not permit any electric appliance (such as a light, telephone, radio, or television) within five (5) feet (1.52m) of a spa or hot tub.

•  The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.

•  Water temperature in excess of 100°F (38°C) may be hazardous to your health. 

WARNING

A terminal bar marked “GROUND” is provided within the controller. To reduce the risk of electrical shock which can cause serious injury or 
death, connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous copper conductor  
having green insulation and one that is equivalent in size to the circuit conductors supplying this equipment, but no smaller than no. 12 AWG 
(3.3mm2). In addition, a second wire connector should be bonded with a no. 8 AWG (8.4mm2) copper wire to any metal ladders, water pipes, 
or other metal within five (5) feet (1.52m) of the pool/spa. In Canada the bonding wire must be minimum 6 AWG (13.3mm2). 

CAUTION

A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load  
side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional 
conductors are also protected by a ground-fault circuit interrupter. Refer to local codes for complete details.

Attention Installer:

Installer to provide drainage of compartment for electrical components.

SAVE THESE INSTRUCTIONS

3

WARRANTY

For product registration visit: www.waterwayplastics.com.

For Warranty questions or claims please contact point of purchase.

Summary of Contents for Oasis 770-1004-PSW

Page 1: ...TRUCTION MANUAL POOL SPA CONTROL 2200 E Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 waterway waterwayplastics com www waterwayplastics com Designed Engineered Manufactured in the...

Page 2: ...ld consult a physician before using a spa or hot tub and should limit spa water temperatures to 100 F 38 C Water temperature in excess of 38 C 100 F may be injurious to your health c Before entering a...

Page 3: ...ne radio or television within five 5 feet 1 52m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in...

Page 4: ...Hardware Mounting Hardware Mounting bracket Mounting Bracket Mounting Bracket for remotely installing UI Mounting Bracket for remotely installing UI Cover plate for UI housing Cover plate for UI hous...

Page 5: ...nted The four 4 mounting holes are 3 15 16 10 cm apart center to center NOTE Make sure to mark out the four 4 holes as accurately as possible 4 Drill four 4 holes in the mounting surface 5 Press the f...

Page 6: ...ician may conveniently access it All high voltage wiring must be done by a licensed electrical contractor NOTE See Figure 10 4 OASIS Electrical Wiring Diagram on page 10 for specific wire locations an...

Page 7: ...a Light Booster Pump etc Connect only one device per relay For each device 1 Connect ground wire to ground bar 2 Connect line power to Line 1 and Line 2 3 Connect equipment power to Load 1 and Load 2...

Page 8: ...the filter before the heater 2 Install the O ring on the sensor and insert the sensor into the hole Wrap and tighten metal clamp around the pipe to secure sensor 5 1 Wire the Temperature Sensors Wire...

Page 9: ...e OASIS Wifi to the JP4 RS 485 connector see Figure 10 4 Wiring Diagram 1 Feed wire through the black low voltage wiring knockout 2 Connect the Black White Green and Red wires as shown in Figure 8 5 2...

Page 10: ...SOLAR J4 OPTION FILTER PUMP AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 GROUNDING BAR WATERWAY OASIS TOPSIDE PANEL BREAKER BOX GROUND NEUTRAL OASIS WI FI KIT BLOWER FILTER PUMP J1 INTAKE J2 RETURN SOLAR TEMP SENSO...

Page 11: ...ERWAY OASIS TOPSIDE PANEL BREAKER BOX GROUND NEUTRAL OASIS WI FI KIT Variable Speed Connector Filter Pump High Filter Pump Low BLOWER FILTER PUMP J2 RETURN SOLAR TEMP SENSOR AIR TEMP SENSOR WATER TEMP...

Page 12: ...Controller for a Variable Speed pump it is important to select the correct pump WWVSP PD VSC165 PD VSC270 WWVSP2 PD 165 PD 225 PD 270 PD 300 Intel VSP Pentair IntelliFlo pumps Hayward VSP select Hayw...

Page 13: ...OWER DEFENDER 140 PUMP BLACK COM WHITE B GREEN A OASIS WWVSP2 CONNECTION TO POWER DEFENDER 165 225 270 PUMP Figure 12 Jandy Pro Series VSP Connection to Pump JANDY PRO SERIES VSP CONNECTION JANDY VSP...

Page 14: ...display Pool Set Temp with the current pool set temp In SPA mode it will display Spa Set Temp with the current spa set temp After 5 seconds without any change to the set temperature the screen will re...

Page 15: ...be assigned to any option Move between items in the left column with UP and DOWN Use the MENU or RIGHT button to navigate between columns By default the right column shows Not Used To change this set...

Page 16: ...ress MENU RIGHT to toggle the selection between am pm or 24 hour selection Heat Source this option can only be changed if a Solar valve or Heat Pump is selected in Assign Output as shown below Then He...