Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction 

outlets can result in an increased potential for suction entrapment as described on the previous page.

This fitting is rated at 244 GPM when mounted on the floor and 216 GPM when mounted on the wall when 

only one port on the center of the sump is used. This fitting is rated at 320 GPM when mounted on the floor 

and 240 GPM when mounted on the wall when two ports on the sump are used. If the fitting is missing or 

broken, replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in 

entrapment of the body which could result in serious injury including drowning.
Do not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per 

instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a 

missing, broken or improperly secured suction grate may result in serious personal injury including drowning.
When the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must 

be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or 

hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur.

Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material, 

can result in an increased potential for suction entrapment as described on the previous page.
Suction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at 

least every seven years, or if found to be damaged, broken, cracked, missing, or not securely attached.

WARNING

Do not exceed the safe flow rate.  Do not increase flow through system by increasing pump size or horsepower.

Do not allow children to sit, play or interact with main drains or suction outlet.

In order to remove the suction cover (for service or winterization), using a Phillips-head screw driver remove 

the screws. Inspect both the suction cover and suction fitting for any cracks or damages.

Any and all broken or missing parts must be replaced prior to starting spa or pool pump.  Never operate spa or 

pool without drain cover in place and properly affixed, death or serious injury can result.

It is imperative to securely attach the suction cover to the wall fittings (use only the original supplied  screws 

or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for 

damaged/tampered with suction fittings is required.
Use 2.5" schedule 40 PVC pipe. 

810-0230.0221

©2021 Waterway Plastics

TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

SAVE THESE INSTRUCTIONS.

•  Installation of a vacuum release system,  
  which relieves entrapping    

 

  suction, is recommended.
•  SOFA(s) should be chosen so that the    
  individual suction system flow rate is >  

   

 

 

pumping system’s MAX system flow rate.

•   Never use a pool or spa if any suction outlet component is damaged,  
  broken, cracked, missing, or not securely attached.
•   Replaced damaged, broken, cracked, missing, brittle, or not securely  
  attached suction outlet components immediately. 

All other applicable National, State, and local codes and requirements shall be followed. 

Summary of Contents for 640-134x V

Page 1: ...rt installation of screws by hand to ensure proper thread engagement and prevent cross threading Replacement cover shall be only used onWaterway sump and mud rings All cracked or damaged mud rings or...

Page 2: ...e wall fitting after installation SOFA installation components with crack chunks or pieces broken off stripped screw holes brittleness and or unusual discoloration should be replaced The mounting surf...

Page 3: ...on the previous page Suction outlet components have a finite life The cover grate should be inspected frequently and replaced at least every seven years or if found to be damaged broken cracked missin...

Page 4: ...9910 2 Pipe Plug 3 6 642 1300 32 3 PortVinyl Liner Sump 1 7 715 1360 32 Plaster Cover Plug 1 5 6 7 4 3 2 1 Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tool...

Page 5: ...U Gasket 1 6 715 9910 2 Pipe Plug 3 7 642 1300 32 3 PortVinyl Liner Sump 1 6 7 4 5 3 2 1 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrica...

Page 6: ...ster Sump 1 5 715 1360 32 Plaster Cover Plug 1 4 3 1 2 5 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tighten...

Page 7: ...4 715 1360 32 Plaster Cover Plug 1 1 2 3 4 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tightening the screws...

Page 8: ...t is used Pressure tap located 19 25in downstream of port in 2 5in DIA schedule 40 PVC pipe When two outside ports used Pressure tap located 29 5in downstream of port in 2 5in DIA schedule 40 PVC pipe...

Page 9: ...THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FLOW PATH ZONE NOTE No reductions in plumbing size are permitted within 16...

Page 10: ...icated sumps shall be made as shown below 32 Min 16 2 38 FRAME PLASTER FINISH SURFACE OF THE POOL 32 Min 2 37 FRAME PLASTER FINISH SURFACE OF THE POOL 5 8 2 PIPE FRAME Part 642 1360 PLASTER FINISH SUR...

Reviews: