4. User Safety

Element cover

Do not remove the element cover as this will expose 230 V wiring and must only be removed by a suitably qualified 
tradesperson.

Thermostat Setting

Must only be adjusted by an electrician or other suitably qualified tradesperson.

Damaged Components

If any component is damaged, it must be replaced by a suitably qualified tradesperson using Protank replacement 
parts only.

Hot Pipe Work

Care should be taken not to touch the pipe work around the cylinder as it could cause scalding.

Turning the Cylinder Off and On

If you plan to be away for an extended period it makes sense to switch the power supply off. When switching back 
on, remember that the cylinder will take a few hours to re-heat.

Draining and Filling the Cylinder

This should only be performed by a qualified tradesperson.

5. Pipe Work

It is the installer’s responsibility to adequately size the distribution pipe work to ensure sufficient performance 
from all outlet fittings. Water pipe sizing should be performed in accordance with AS/NZS 3500.4 and/or G12 AS1. 
Contact Waterware for advice on system sizing and design.

6. Maintenance and Servicing

Hot water systems require regular maintenance and servicing to ensure longevity and trouble free operation. We 
recommend the following procedures be followed;

Every 6 Months:

Operate and vent water from the temperature & pressure relief* valve.

Every 5 Years Thereafter:

Inspect all connections and the heating element** if installed in hard water areas.

*TPR Valve

This valve is the highest mounted valve on the side of the cylinder and is an essential safety valve. It works by 
automatically venting hot water if the temperature or pressure of the water in the cylinder exceeds its presetting. 
Rotate the red knob approximately ¼ of a turn and hold in that position for 5 seconds while hot water is vented 
into the drain. This helps clear any naturally occurring lime deposits that may cause it to malfunction. If it fails to 
vent any water or continues to vent water when released, immediately switch off the power and call a qualified 
tradesperson to arrange an inspection.

**Heating Element

In hard water areas the element(s) may need to be periodically descaled by a suitably qualified tradesperson. To do 
this the unit must be drained and the element(s) removed.

7. Troubleshooting

Do not attempt to carry out any work other than that mentioned in this troubleshooting section. If you have any 
other faults or problems, please contact qualified tradesperson or Waterware.

No hot water

•  Is there an electricity supply to the cylinder?

•  Check that the isolating switch marked ‘hot water’ or ‘water heater’, at the meter box, is switched on. Also 

check any isolating switches near the water heater are switched on.

•  Check the fuse or circuit breaker marked ‘hot water’ or ‘water heater’ at the meter box. Repeated failure 

Summary of Contents for Protank 120L

Page 1: ...1 waterware co nz HOT WATER CYLINDERS Owners Manual 120L 180L 250L 350L and 400L 2019v1 ...

Page 2: ... Essential Installation Requirements 4 3 Safety Devices 4 4 User Safety 5 5 Pipe Work 5 6 Maintenance and Servicing 5 7 Trouble Shooting 6 8 Water Quality 7 9 Single Domestic Residence Limited Warranty 8 10 Installer Contact Details and Proof of Purchase 10 ...

Page 3: ...3 CALEFFI MONO BLOCK VALVE SET COLD WATER EXPANSION VALVE ELEMENT THERMOSTAT COVER TEMPERATURE PRESSURE RELIEF VALVE ...

Page 4: ...s on models 250L and over Textured white powder coated external finish 2 Essential Installation Requirements Drip Trays A hot cylinder is a vessel containing water which has the potential to unexpectedly leak water To minimise damage to other areas of your home ensure that your cylinder has been installed with a drip tray consequential damage resulting from the absence of a drip tray will not be a...

Page 5: ...perate and vent water from the temperature pressure relief valve Every 5 Years Thereafter Inspect all connections and the heating element if installed in hard water areas TPR Valve This valve is the highest mounted valve on the side of the cylinder and is an essential safety valve It works by automatically venting hot water if the temperature or pressure of the water in the cylinder exceeds its pr...

Page 6: ... outlet is turned off and check your water meter to ensure it is not still flowing 8 Water Quality Some NZ water supplies are particularly aggressive and can cause premature damage and reduced life expectancy for hot water cylinders or any other appliance connected to them Protank hot water cylinders are manufactured by RM Cylinders in the UK from the highest quality Duplex 2304 stainless steel wh...

Page 7: ...R costs to replace or repair the cylinder if it fails due to manufacturing defect Followed by 5 YEARS FREE PARTS ONLY costs excluding labour to replace or repair the cylinder if it fails due to manufacturing defect Followed by 10 YEARS PRO RATA PARTS ONLY reducing costs excluding labour according to the below formula to replace or repair the cylinder if it fails due to manufacturing defect Pro Rat...

Page 8: ...e replacements will carry a new warranty 7 Waterware reserve the right to have the installed product returned to the factory for inspection if required 8 Where the cylinder is installed outside the metropolitan area or further than 40 km from a Waterware nominated service agent travel costs shall be the owner s responsibility 9 Waterware reserves the right to replace the cylinder for another type ...

Page 9: ...and Proof of Purchase Your Protank serial number see data label Installation by company name and address Installers name Phone Mobile Signed Date Retailer company name and address Phone Date of purchase Attach proof of purchase here ...

Page 10: ...waterware co nz info waterware co nz 64 9 273 9191 ...

Reviews: