INSTALLATION OF INFINITY

  

FILTER CARTRIDGE INSTALLATION

STEP 

1

Push down the top cap with both hands.

STEP 

4

Look down into the tank assembly, and you should see  

a small opening centered in the bottom of the tank.

STEP 

7

Press down on the filter cartridge so that the double O-ring 

seal moves into place within the bottom, center opening.

STEP 

10

Pull up on the Top Cap to seat o-rings.

STEP 

2

Remove the retaining ring by carefully grasping the handle 

and pulling inward, then upward. The retaining ring should 

slide completely out of the groove.

STEP 

5

Remove packaging from filter cartridge, then place the filter 

cartridge into the tank with the double O-ring facing down.

STEP 

8

Reposition the Top Cap into its original location.

STEP 

11

Place Umbrella Cap on top of system.

STEP 

3

Remove the Top Cap from the housing assembly by pulling 

the cap out of the top of the tank, by lifting up on the top 

handles. Place removed Top Cap on a clean and dry surface, 

free of debris, so no contamination of the o-ring occurs.

STEP 

6

Position the cartridge so that it is aligned  

with the bottom, center opening.

STEP 

9

Reattach the top tank Snap Ring.

STEP 

12

Run water through system for 

10 minutes 

before use.

10

4

Summary of Contents for INF-GUARD1

Page 1: ...INSTALLATION OPERATION MANUAL MODEL INF GUARD1 MODEL INF SEN1...

Page 2: ...d to be used on municipally treated water sources Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system Filter usa...

Page 3: ...INSTALLATION OF INFINITY WHERE TO INSTALL 1 CITY WATER INLET WATER METER SERVICE SERVICE WELL INLET RELIEF VALVE MUST BE INSTALLED PRESSURE TANK PUMP WELL WATER CITY WATER...

Page 4: ...ilter INF SEN1 FX OR INF GUARD1 FX DRAIN VALVE IMPORTANT Bypass Orientation INLET OUTLET Flow direction arrows on bypass are incorrect for this filter application Plumb unit opposite of arrows 6 10 11...

Page 5: ...n NOT PROVIDED STEP 4 OPTION B Use 7 90 degree Angled In Out 1 MNPT for connecting your plumbing to the system HAND TIGHTEN ONLY STEP 5 Install part 4 into 3 using the threaded connection Teflon tape...

Page 6: ...g should slide completely out of the groove STEP 5 Remove packaging from filter cartridge then place the filter cartridge into the tank with the double O ring facing down STEP 8 Reposition the Top Cap...

Page 7: ...OTE Due to unknown water quality and water usage it is recommended to replace filter annually for a household of 4 people 1 SENTINEL Filter Replacement Part Number INF SEN1 FX GUARDIAN Filter Replacem...

Page 8: ...d John Guest fitting and shut off that connects to the inlet side of the filtration system Run the hose to a floor drain or bucket and use to drain sediment or to aid in filter removal during change o...

Page 9: ...down until all the air pressure is completely released and water comes out of the red depressurization button STEP 21 Check for leaks STEP 13 Reposition the Top Cap into its original location STEP 16...

Page 10: ...design and application Results may vary This pressure vessel is tested and certified by NSF International against NSF ANSI Standard 44 and 61 for materials and structural integrity requirements SPECI...

Page 11: ...onal users 7 THIS WARRANTY EXCLUDES THE FOLLOWING a Damage caused by improper installation operation or care b Damage caused by chemical attack environment accident fire flood freezing Act of God misu...

Page 12: ...WaterTech 800 Freeport Pkwy 150 Coppell TX 75019 469 521 1180 CustomerSupport WaterTech com www WaterTech com...

Reviews: