Designation model Waterstage High Power
11 Single
phase
14 Single
phase
11 3-Phase 14 3-Phase 16 3-Phase
Nominal heating performances
(outdoor temperature / initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system
kW
10,80
13,50
10,80
13,50
15,17
-7 °C / +35 °C - Floor heating system
kW
10,80
12,00
10,80
13,00
13,50
+7 °C / +45 °C - Low temperature radiator
kW
9,23
11,54
10,10
12,60
13,00
-7 °C / +45 °C - Low temperature radiator
kW
9,16
11,45
10,02
12,50
13,00
+7 °C / +55 °C - Radiator
kW
7,74
9,67
9,48
11,80
12,96
-7 °C / +55 °C - Radiator
kW
7,51
9,25
9,20
10,60
11,90
Power absorbed
+7 °C / +35 °C - Floor heating system
kW
2,54
3,23
2,51
3,20
3,70
-7 °C / +35 °C - Floor heating system
kW
4,32
5,08
4,28
5,18
5,40
+7 °C / +45 °C - Low temperature radiator
kW
2,84
3,72
3,01
3,81
4,00
-7 °C / +45 °C - Low temperature radiator
kW
4,58
5,92
4,63
6,00
6,37
+7 °C / +55 °C - Radiator
kW
3,13
4,03
3,60
4,61
5,14
-7 °C / +55 °C - Radiator
kW
4,56
5,65
5,08
6,04
6,88
Coefficient of performance (COP)
(+7 °C / + 35 °C)
4,25
4,18
4,30
4,22
4,10
Electrical characteristics
Supply voltage (50 HZ)
V
230
400
Maximum current for appliance
A
22
25
8,5
9,5
10,5
Nominal current
A
11,4
14,2
3,7
4,8
5,5
Maximum current of the electrical back-ups
A
26,1
13
Power of the electrical back-ups
kW
ajustable 3 or 6 kW (phase)
9 kW (3-phase)
Real power absorbed - by the fan
W
2x100
2x104
- by the circulation pump
W
70
Maximum power absorption by the outdoor unit
W
5060
5750
5865
6555
7245
Hydraulic circuit
Maximum operating pressure
bar
3
Hydraulic system flow rate (mini/maxi) 4°C<Δt<8°C (nominal conditions)
l/h 1170 / 2340 1460 / 2920 1170 / 2340 1460 / 2920 1650 / 3290
Various
Weight of outdoor unit
kg
92
99
Noise level at 1 m
1
(hydraulic unit)
dB
39
Sound power level according to EN 12102
2
(hydraulic unit)
dB
46
Noise level at 5 m
1
(outdoor unit)
dB
42
43
39
41
42
Sound power level according to EN 12102
2
(outdoor unit)
dB
69
70
66
68
69
Weight of hydraulic unit (empty / full of water)
kg
44 / 60
Water capacity of the hydraulic unit
l
16
Heating system operating limits
Hydraulic unit operation range
°C
0 / +45
Outdoor temperature mini/maxi
°C
-25 / +35
Initial max. heating water temperature Floor heating system
°C
45
Initial max. heating water temperature Low temperature radiator
°C
60
Flow min. heating water temperature
°C
8
Refrigeration circuit
Diameter of gas pipes
inches
5/8
Diameter of liquid pipes
inches
3/8
Factory charge of refrigerant R410A
3
g
2500
Maximum operating pressure
bar
42
Minimum length of pipes
m
5
Maximum length of pipes
4
m
15
Maximum length of pipes
5
m
20
Maximum level difference
5
m
15
1 3 Specifications
1
Sound pressure level in (x)m of the device, 1,5m of the ground, the open field.
2
The sound power level is a laboratory measure of the emitted sound power
but contrary to the noise level, it doesn't correspond to the measure of the felt.
3
Refrigerant R410A (as per the standard EN 378.1).
4
Factory charge of refrigerant R410A.
5
Taking into account the possible additional load of refrigerant R410A (see
.
Installation and operating manual "1533 - EN"
- 5 -
Air to Water Heat Pump