Impeller Cleaning
1. Unplug the pump.
2. Remove the three screws shown in the figure.
3. Remove the cover and carefully clean the impeller of all debris.
4. Before reattaching the cover, carefully reposition the gasket making sure it will not
obstruct the pump openings.
5. Reinstall the cover and replace the screws using caution as to not over-tighten or
strip the screws.
Key Pumping Considerations
1. A 12V DC battery source power source is required for the HydraPump® 12V Utility
Submersible to operate. It must be an adequately charged battery, preferably a fully
charged battery since it will offer the best experience.
2. The pump should be in the off position when making the battery connections.
3. Check that the water source and piping are clear of dirt, scale, and sand. Debris will
clog the pump. The pump is meant for clean/clear water.
4. The pump and its piping cannot operate below freezing.
5. The pump motor is in a fully enclosed oil filled compartment which helps with keeps
the pump cool during operation. Also, the pump should not operate without water
present for extended periods but if it does: unplug the pump and check the pump for
damage.
06
03
Cleaning & Maintenance
Always disconnect the power source before attempting to
clean the impeller.