background image

•  Quality of the Water and Filters My Perfect Colon:

 ◦

Use clean running water or, if you have any doubts about the quality, use My Perfect Colon water 

filters. Alternatively, use bottled water; 

 ◦

Use of the filter D is optional. If you want to use it, fit between the C4 tube fitting and the F tube; 

 ◦

By mounting the filter, the quantity of water supplied is slightly reduced and in proportion to the 

quality of the water (the more impurities are present in suspension in the water, the more the flow 

tends to be reduced - see table 1 as a reference for the quantity of water supplied for each session 

under normal conditions); 

 ◦

Warning:  Never  use  the  filter  for  multiple  irrigations.  Replace  the  filter  after  each  irrigation  to 

ensure the purity of the water, an adequate flow, and avoid the proliferation of bacteria between one 

irrigation and the next. Replacement filters are available on the website www.myperfectcolon.com e 

www.waterpowered.eu. 

RECHARGE MANAGEMENT

•  The supplied cable has a USB socket. To recharge the device, connect the cable to the charging socket 

(C2) of the device and the other end to a common charger with a USB port (not supplied);

6

•  Make sure that the flow in the tubes is not blocked or slowed down by obstructions or kinks;

•  During irrigation, position the bag at the height of about 1m, thanks to the suction cups supplied. Where 

the bag is placed on the ground, position it slightly on a slope so that the water is directed towards the 

outlet to avoid sucking in air;

•  Emptying: after completing the insertion of water, the intestine will begin to empty. Especially during the 

first few uses, it may be necessary to wait a few minutes, even 15-30 minutes, before the colon begins 

to empty. Make sure to expel all the water. To facilitate emptying, try bending forward, coughing, and/

or doing an abdominal massage;

•  Evacuation times are subjective and may vary from session to session.

•  Amount of water:

 ◦

For every 30” session, about 475ml of water is dispensed (considering the position of the bag at about  

1m of height); 

 ◦

If you prefer less water flow, connect the reducer between the connection of the outlet tube (C4) and 

the tube F (fig. 2): in this way there will be a reduction of about 30% of the flow rate compared to the 

normal one when the reducer is not mounted (fig. 1). If you prefer an even lower flow (approx. -70%), 

connect the reducer (E) between the suction tube (B) and the water inlet fitting (C3 - fig. 3). See the 

table below for the specification on the different flow rates; 

 ◦

Depending on the height at which the bag is positioned, the amount of water dispensed per minute 

may vary (the lower the bag is positioned, the lower the amount of water dispensed).

Table 1 - Amount of Water per Session according to the different Configurations - considering the 

device fully charged and the bag positioned at about 1m of height - (toler. +/-20%)

Time / Session 

of 30”

Without 

reducer and 

filter E (fig.1)

With Reducer 

(E) on Outlet 

tube (fig.2)

With Reducer 

(E) on Inlet 

tube (fig.3)

With Filter (D)

on the outlet 

tube  

With Filter (D) 

and Reducer 

(E) on the 

outlet tube

30 ” / 1 

Session

475ml approx. 325ml approx.  150ml approx.  375ml 

275ml 

60 ” / 2 

Sessions

950ml approx. 650ml approx.  300ml approx. 750ml 

550ml

120 ” / 3 

Sessions

1425ml 

approx.

975ml approx.  450ml approx. 1125ml 

825ml

Summary of Contents for My Perfect Colon Pro

Page 1: ...EN User guide www waterpowered eu customer waterpowered eu 800577477...

Page 2: ...E E 200 400 600 800 1000 1200 1400 1500 36 C 38 C H O Approx ml A B B1 D x5 F I x12 J H C G C2 C1 C3 C4 C 2A 1 2 3 E E 2 General Diagram...

Page 3: ...Do not use the device if it has a damaged cable or socket if it does not work correctly if it has fallen is damaged or been dropped in water In this case contact Water Powered srl Keep the cable away...

Page 4: ...endoscopic polypectomy Ischemic colitis Children under 3 years of age For children it is always necessary to consult their doctor before use Women during pregnancy planned pregnancy or breastfeeding S...

Page 5: ...ube clamp B1 and start irrigation by pressing the power button C1 the indicator light will turn on read the paragraph Instructions for irrigation 13 To stop water supply press the C1 button To be awar...

Page 6: ...sertion of water the intestine will begin to empty Especially during the first few uses it may be necessary to wait a few minutes even 15 30 minutes before the colon begins to empty Make sure to expel...

Page 7: ...andle To periodically clean the internal surface of the tubes and the bag fill the bag with water and mild natural soap and start the device to let the water flow into the tubes draining into the sink...

Page 8: ...the product after finding a fault the use of unsuitable operating methods and failure to observe the instructions of use and maintenance The manufacturer assumes no responsibility for any difficultie...

Page 9: ...ns 11 class A Harmonics EN 61000 3 2 class A Flicker pst dt dc Field V m Frequency Modulation 3 80MHz 2700MHz 1kHzAM80 27 380MHz 390MHz 18HzPM50 28 430MHz 470MHz 18HzPM50 9 704MHz 787MHz 217HzPM50 28...

Page 10: ...es the device and other equipment must be kept under observation to verify their regular operation PortableRFcommunicationsequipment includingperipheralssuchasantennacablesandexternalantennas should b...

Reviews: