2. Ensure the tube clamp (B1) on tube B is tight and fill the bag with warm water (between 36 ° and 38 ° - 

check the temperature highlighted in green/brown on the thermometer affixed to the bag. If no colored 

dot appears, the water temperature is higher or lower than the thermometer range. The value is indicative 

- tol/- 10%);

3. Close the bag by screwing the cap well, fix it to the wall (smooth and clean surface) or a mirror thanks to 

the suction cups at the height of about 1m or place it on the floor or a stable surface; Position the bag 

near the toilet bowl so that the tube clamp (B1) can be reached by hand when seated;

4. Connect the other end of the suction tube (B) to the water inlet fitting (C3) located on the handle;

5. Connect the 1-metre tube (F) to the water outlet tube fitting (C4) located on the handle C;

6. Connect the other end of the tube F to the support (G) and apply the suction cups to the front of the 

toilet seat or the toilet itself;

7. Connect the tube fitting of the suction cup holder (G) to the modeling tube (H);

8. Connect the cannula (I) to the modeling tube (H);

9. Unlock the tube clamp (B1) to allow the passage of water and, placing the cannula (I) inside the toilet, press 

the power button C1; run the water through the tubes for a few seconds to check the correct connection 

and operation (it is possible that the air present in the empty tubes is initially sucked and expelled);

10. Switch off the device by pressing the C1 button, tighten the tube clamp (B1) and sit on the toilet, 

placing the tubes between the legs;

11. Gently insert the cannula into the rectum without forcing it. If you feel resistance to insertion, remove 

the cannula and ensure that the rectum is empty (manual evacuation may be necessary to facilitate 

emptying). Try using lubricating ointments to facilitate insertion. If resistance persists, do not force it, 

stop irrigation and ask for the support of a health professional;

12. Unlock the tube clamp (B1) and start irrigation by pressing the power button C1 (the indicator light will 

turn on - read the paragraph “Instructions for irrigation”);

13. To stop water supply, press the C1 button. To be aware of the amount of water introduced during 

washing, every 30” the device turns off interrupting the supply; this security system prevents more 

water than desired to being inadvertently introduced. Press the power button again to continue the 

irrigation for another 30”. 

To check the amount of water that is dispensed according to the different 

configurations, see table 1 in the paragraph “Instructions for irrigation”;

14. After irrigation, turn off the device by pressing the C1 button and close the tube clamp (B1).

Use for bedridden people:

In case of use by bedridden people, therefore not on the toilet, the mounting of the tube with support and 

suction cups (G) and the modeling tube (H) are not necessary. Connect the cannula directly to the outlet 

tube (F).

Use in supine position

For an even more effective cleanse, it is recommended to carry out washing in the supine position. For this 

purpose, the My Perfect Colon board and the Comfort Wash Mat are available. Accessories available on 

www.myperfectcolon.com or www.waterpowered.eu. In case of use in the supine position, the tube with 

support and suction cups (G) and the modeling tube (H) are not necessary. Connect the cannula directly 

to the outlet tube (F).

Indications for irrigation

•  The amount of water required for transanal irrigation is subjective. For adults, it can vary from 300 to 

1,000 ml up to a maximum of 1,500 ml (according to the instructions of your doctor). For children, 10-20 

ml for each kg of weight. The bag can contain a max. of 2 liters of water;

•  Use water between 36°C and 38°C. If the water is too hot, it can damage the delicate lining of the 

intestine. If too cold, stomach cramps can occur. If you feel a temperature that is too hot or cold during 

use, turn off the device and replace the water in the bag with water at the correct temperature. Help 

yourself in regulating the water temperature with the thermometer placed on the bag;

5

Summary of Contents for My Perfect Colon Pro

Page 1: ...EN User guide www waterpowered eu customer waterpowered eu 800577477...

Page 2: ...E E 200 400 600 800 1000 1200 1400 1500 36 C 38 C H O Approx ml A B B1 D x5 F I x12 J H C G C2 C1 C3 C4 C 2A 1 2 3 E E 2 General Diagram...

Page 3: ...Do not use the device if it has a damaged cable or socket if it does not work correctly if it has fallen is damaged or been dropped in water In this case contact Water Powered srl Keep the cable away...

Page 4: ...endoscopic polypectomy Ischemic colitis Children under 3 years of age For children it is always necessary to consult their doctor before use Women during pregnancy planned pregnancy or breastfeeding S...

Page 5: ...ube clamp B1 and start irrigation by pressing the power button C1 the indicator light will turn on read the paragraph Instructions for irrigation 13 To stop water supply press the C1 button To be awar...

Page 6: ...sertion of water the intestine will begin to empty Especially during the first few uses it may be necessary to wait a few minutes even 15 30 minutes before the colon begins to empty Make sure to expel...

Page 7: ...andle To periodically clean the internal surface of the tubes and the bag fill the bag with water and mild natural soap and start the device to let the water flow into the tubes draining into the sink...

Page 8: ...the product after finding a fault the use of unsuitable operating methods and failure to observe the instructions of use and maintenance The manufacturer assumes no responsibility for any difficultie...

Page 9: ...ns 11 class A Harmonics EN 61000 3 2 class A Flicker pst dt dc Field V m Frequency Modulation 3 80MHz 2700MHz 1kHzAM80 27 380MHz 390MHz 18HzPM50 28 430MHz 470MHz 18HzPM50 9 704MHz 787MHz 217HzPM50 28...

Page 10: ...es the device and other equipment must be kept under observation to verify their regular operation PortableRFcommunicationsequipment includingperipheralssuchasantennacablesandexternalantennas should b...