OVERHAUL - DIRECT MOUNTED PUMP
Page 8 of 13
Copper Washer, 3/8 in.
Socket Hd Screw,
Mechanical Seal
3/8-16 x 2-3/4 in.
O-ring, 1 x 1-1/8 in.
Shaft Sleeve
Pump Adapter with Wear Ring
O-ring, 7-3/4 x 8 in.
Stationary Seal Ring
1.
Remove the (4) socket head cap screws and copper washers holding the pump adapter to the engine.
2.
Remove the pump adapter.
3.
Press out the mechanical seal stationary seal ring.
4.
Remove the pump adapter O-ring.
5.
Remove wear ring if required.
6.
Remove the shaft sleeve and O-ring.