F-1031, Section 4205.1
Page 10 of 24
Rev: 01/18/08
Removal of Volute Body from Pump Head
1.
Remove the twelve (12) hex head screws and copper washers that attach
the pump head to the volute body.
2.
Separate the pump head from the volute body.
3.
Remove and discard O-ring.
NOTE: The wear rings will remain in the volute body and pump head.
Removing the wear rings from the body or head is necessary only if
they are damaged or badly worn. (See page 19).
Figure 6. Volute Body Removal from Pump Head
Volute Body
Copper Washer
Hex Hd Screw,
7/16-14 x 1 in.
Pump Head
O-ring
Summary of Contents for CP-1 Series
Page 26: ......