background image

 

INSTALLTION FOR 

MINIATURE THERMOSTATIC VALVE

 

 

 

 

P a g e

 | 

2

 

Valve Installation

 

1.

 

Flush the lines of all dirt and debris.  Failure to completely flush the lines will cause valve failure and 

will void the manufacturer’s warranty. 

2.

 

Fit the valve on the wall without removing the plastic cover on the control spindle.  Turning the 

control spindle will change the temperature setting which is pre-calibrated at the factory. 

3.

 

Connect the hot water supply to the left inlet of the valve (hot marked with “H”) and cold supply to 

the right inlet (cold marked with “C”). 

4.

 

Use the 

Plastic Mudguard (1)

 (part of the package) to position the 

Valve (2)

 in the wall.  This is done 

by checking the markings on the mudguard for the minimum/ maximum settings which is 2 3/8” to 2 

7/8” from the center of the valve inlets to the finished wall. 

 

Diagram 2: Plastic Mudguard 

 

 

 

 

 

 

 

 

 

 

 

                       

5.

 

Connect the outlet pipe. Install tile stops/volume controls between the thermostatic valve and each 

device to be operated.  

Trim Installation 

(see Diagram 4)

 

1.

 

Screw 

Temperature Control Dome (1)

 onto valve. 

2.

 

Slide the 

Thermostatic Face Plate (3)

 onto the valve by sliding over the 

Temperature Control Dome 

(1) 

and hold in place. 

3.

 

Screw 

Thermostatic Face Plate Lock Ring (4) 

into 

Dome Sleeve (2)

4.

 

Lock the 

Thermostatic Face Plate (3)

 securely against the wall by screwing 

Dome Sleeve (2) 

with 

Thermostatic Face Plate Lock Ring (4) 

onto 

Temperature Control Dome (1)

5.

 

Ensure 

Temperature Limit Stop Ring (5) 

is installed with red dot at 12 o’clock position 

6.

 

Install 

Temperature Control Post (6)

 onto valve with push button at 12 o’clock position and install 

Temperature Control Handle (8) 

onto 

Temperature Control Post (6)

Note:

 Some heavier lever handles come with friction washers to prevent rotation due to gravity. The 

thicker of these washers is for use with this valve when needed (see Diagram 3). 

 

Diagram 3 

 

                     

 

 

 

 

  