INSTALLTION FOR
MINIATURE THERMOSTATIC VALVE
P a g e
|
2
Valve Installation
1.
Flush the lines of all dirt and debris. Failure to completely flush the lines will cause valve failure and
will void the manufacturer’s warranty.
2.
Fit the valve on the wall without removing the plastic cover on the control spindle. Turning the
control spindle will change the temperature setting which is pre-calibrated at the factory.
3.
Connect the hot water supply to the left inlet of the valve (hot marked with “H”) and cold supply to
the right inlet (cold marked with “C”).
4.
Use the
Plastic Mudguard (1)
(part of the package) to position the
Valve (2)
in the wall. This is done
by checking the markings on the mudguard for the minimum/ maximum settings which is 2 3/8” to 2
7/8” from the center of the valve inlets to the finished wall.
Diagram 2: Plastic Mudguard
5.
Connect the outlet pipe. Install tile stops/volume controls between the thermostatic valve and each
device to be operated.
Trim Installation
(see Diagram 4)
1.
Screw
Temperature Control Dome (1)
onto valve.
2.
Slide the
Thermostatic Face Plate (3)
onto the valve by sliding over the
Temperature Control Dome
(1)
and hold in place.
3.
Screw
Thermostatic Face Plate Lock Ring (4)
into
Dome Sleeve (2)
.
4.
Lock the
Thermostatic Face Plate (3)
securely against the wall by screwing
Dome Sleeve (2)
with
Thermostatic Face Plate Lock Ring (4)
onto
Temperature Control Dome (1)
.
5.
Ensure
Temperature Limit Stop Ring (5)
is installed with red dot at 12 o’clock position
6.
Install
Temperature Control Post (6)
onto valve with push button at 12 o’clock position and install
Temperature Control Handle (8)
onto
Temperature Control Post (6)
.
Note:
Some heavier lever handles come with friction washers to prevent rotation due to gravity. The
thicker of these washers is for use with this valve when needed (see Diagram 3).
Diagram 3