7.7 ICE BATH CIRCULATION ERROR
43
TROUBLESHOOTING
ENG2036-16/01/19
• The circulation motor in the ice bath has faulted
COMMON TROUBLESHOOTING:
1.
Cycle power to ensure error repeats (RESET).
2.
Check all wiring to ensure there is not an open circuit.
3.
Replace circulation motor (chapter 6.1, [83]).
RESET the ERROR by turning OFF and ON after 5 seconds the
red
power switch.
7.8
ICE BATH LEVEL ERROR
• The Ice Bath fill solenoid valve [SV6] has been open for more than 10 minutes during
start-up or more than 1 minute during normal operation. If the Ice Bath fill happens three
times within an hour this error will also show.
COMMON TROUBLESHOOTING:
1.
Check for leaks.
2.
Ensure adequate water supply.
3.
Check to make sure Ice Bath level sensor is properly connected.
4.
Check Ice Bath fill solenoid valve [SV6].
5.
Replace Ice Bath level sensor.
RESET the ERROR by turning OFF and ON after 5 seconds.
7.9
DISPENSE TIME OUT
• Indicates a 2 minute continuous dispense has been detected in operating mode.
COMMON TROUBLESHOOTING:
1.
Release dispense button.
2.
Damage to front dispense control knob. Replace front display PCB control knob. [13]
3.
Moisture on front control knob PCB shorting signal to main PCB. Ensure PCB board and
controls are dry and protective covers and seals are in place.
4.
Wire short circuit. Inspect and check all harness and wiring for damage.