WL3000 Technical Manual - May 2014
Instructions
on Changing the CO
2
Bottle
REMOVING THE EMPTY BOTTLE
Turn off the empty bottle and disconnect from gas regulator.
CONNECTING NEW BOTTLE
• Before connecting new bottle, remove dust cap.
• Face the gas bottle away from yourself and open for 3-5 seconds to release any
air from the top of the bottle.
• Connect bottle to gas regulator, and turn on. The pressure should read 3 Bar.
Adjust if needed.
PURGING THE MACHINE
• Lift the yellow lever under top cover for 5-10 seconds to purge the gas line
and carbonator.
• Place a container of at least 1 litre under the faucet and dispense sparkling water
until just gas is dispensed from the faucet.
• The machine will now refill. This takes about 1 minute.
• When the pump has stopped turn the gas bottle off.
• Record the regulator pressure, normally 3 Bar.
• After 5 minutes check the gauge for any pressure drop as this indicates a leak.
INSTALLATION KIT
The WL3000 must be installed according to the local guidelines and a pressure
reducer must be installed as part of the installation. The pressure reducer should
not be set higher than 3bar.
• The WL3000 should not be connected to water supplies of unknown bacterial
quality or those not already fit for human consumption. The WL3000 should only be
connected to a potable drinking water supply.
• The filter on the WL3000 must be changed every 6 months.
• The UV lamp on the WL3000 must be changed every 6 months.
• The cold tank should also be flushed and sanitized every 6 months.
• Waterlogic International strongly recommends the use of an anti-flood device.
• Figure 1 is the recommended installation kit.
The part number for the installation kit shown below is “P-KIT INSTALLATION”.
1. 15 mm Compression Inlet
2. Double Check Valve (great for carbonated water)
3. Adjustable Pressure Reducing Valve
4. Integral Isolator (with green adjustment knob)
5. Pressure Gauge Port
6. Waterblock
7. 1/4" Pushfit Outlet
Fig. 1
1
2
6
4
7
3
5