WL3 FX
Manual
Page 72 - Revision: 7-27-2022
8.
Hot Water Coming out of Faucet Vent Hole
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
WL3 FX
Water Treatment
System
to operate properly.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 40-60 psi.
Improper tubing attachment
from the tank to faucet or vice
versa.
Verify tubing is connected properly from tank outlets to correct
faucet attachments.
Hot Tank outlet hole is scaled
over.
Inspect and Descale Tank as needed.
See Hot Tank Descaling Instructions that are included further
below in this Troubleshooting Section.
See instructional video on the Partner Area of the Waterlogic.com
website for more information.
Expansion chamber is not
sealed properly.
Replace the Hot Tank.