WL3 FX
Manual
Page 55 - Revision: 7-27-2022
WL3 FX COUNTER TOP DRAINING INSTRUCTIONS
Draining Notes
Drain the
WL3 FX
Water Treatment System
for transportation.
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and
reduce microbial growth).
Prior to draining the hot tank, turn off the Green Heater and Compressor Power
Switch (
O=OFF)
, and dispense 2 liters of hot water from the machine. As hot water
is dispensed from the faucet of the
WL3 FX Water Treatment System
, colder water
will be introduced into the hot tank. Since the Green Heater and Compressor
Power Switch is turned off, the heater will not energize and heat the incoming tap
water. Following this precaution prevents exposing personnel and equipment
(drains, catch basin, etc.) to scalding hot water.
Disable Cold and Hot Tanks
1.
Turn off the Green Heater and Compressor Power Switch (
O-OFF
) to disable the
heater and compressor.
2.
Dispense 2 liters (1/2 Gallon) of water through the hot tank to cool the water
temperature in the hot tank and avoid burns.
WARNING!
HOT WATER.
The
WL3 FX
Water Treatment System
produces Hot Water
up to 87
°
C (188
°
F).
Water above 52
°
C (125
°
F) can cause severe burns or scalding. Hot
water should be dispensed carefully into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
3.
Isolate the
WL3 FX
Water Treatment System
from feed water by turning off the supply.
4.
Dispense cold still water to relieve any pressure built up in the system.
5.
Remove the top lid and front panel of the unit to reveal the drain ports at
the bottom of the machine.
It is recommended to move the machine over a
sink or place a container under the valves to catch drain water.
6.
Unscrew the cap of the Cold Drain port and Press and Hold the Cold Water
Dispense Button until all Cold Water has drained from the
WL3 FX
Water
Treatment System out of the inlet port.
Replace cap when finished.
7.
Repeat this procedure for the Hot Tank by using the Hot Valve and double pressing and
holding the Hot Dispense button until all hot water has drained from the
WL3 FX
Water
Treatment Machine
. Replace the cap when finished.