background image

WL3 Technical Manual - Version 1, July 2014

30

31

Electrical Wiring Diagram 230V

End of Life

Non Eu Countries

At the end of this products life, please ensure that it is disposed of in an environmentally 

friendly manner which is in line with your Country requirements/guidelines.

WEEE (EU ONLy)

Please be aware that our products are covered by the Waste Electrical and 

Electronic (WEEE) directive (2002/96/EC).  The symbol shown above denotes 

that the product should not be disposed of with general/household waste. Please 

contact your supplier/service agent who will arrange for the collection and disposal 

of this product.

ROHS

All Waterlogic machines comply with EC Directive (2002/95/EC) on the Restriction of 

the Use of Certain Hazardous Substances in Electrical and Electrical Equipment (RoHS

).

BIOCOTE® (ANTI-MICROBIAL SOLUTION)

For your added protection this product incorporates BioCote® antimicrobial 

technology. Silver, in the form of silver ions, is the active ingredient utilised in 

BioCote®. This silver technology is manufactured into the surface of our products, 

giving them built-in sustainable antimicrobial protection.  BioCote’s silver technology 

has been tested by an independent laboratory to show its ability to inhibit the 

growth of bacteria, mould and fungi by up to 99.9% over a 24 hour period and for 

the duration of the machine life.

FREQUENTLy ASKED QUESTIONS ABOUT BIOCOTE®:

Why use BioCote®?

 

BioCote® will help reduce the risk of cross-contamination. You 

may not want to think about it, but every surface in the working environment is a 

potential breeding ground for Bacteria.

How is it applied? 

BioCote® is applied via an additive into the manufacturing 

process and will, therefore, be present throughout the moulded or painted parts. 

How long will BioCote® last?

 

BioCote® will last for the usual life expectancy of 

your water dispenser. It will not wear or wash out with use or cleaning.

What bacteria is BioCote® effective against?

 

BioCote® is effective against most 

common bacteria, moulds and fungi.

Please note:

 

BioCote® is an additional line of defence to protect between cleaning routines, it is 

not a replacement for your normal cleaning and sanitisation processes.

DANGER HIGH VOLTAGES PRESENT ON THIS PCB

CARE MUST BE TAKEN WHEN LIVE TESTING

Summary of Contents for WL3 Firewall

Page 1: ...WL3 Firewall Technical Manual...

Page 2: ...ent not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses and by cli...

Page 3: ...ore the Activated Carbon process will remove a whole range of contaminants e g chlorine and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achie...

Page 4: ...ation tank at a minimum pressure of 3 2 bar This pressure is required to overcome the internal pressure from the CO2 gas which is in the tank IN FAUCET UV The Unique design allows the faucet area to b...

Page 5: ...VALVE WATER IN SPARKLING WATER OUT SOLENOID VALVE PUMP CHECK VALVE CO2 In SPARKLING TANK SAFETY VALVE COLD SENSOR COLD TANK SUCK BACK SOLENOID VALVE CHECK VALVE HOT WATER OUT HOT WATER OUT AIR VENT S...

Page 6: ...VALVE SOLENOID VALVE SPARKLING WATER OUT COLD SENSOR COLD TANK SOLENOID VALVE SUCK BACK SOLENOID VALVE CHECK VALVE AMBIENT WATER OUT COLD WATER OUT SOLENOID VALVE Wetted Parts Layout Cold Ambient and...

Page 7: ...als could present a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used CO2 gas cylinders used for sparkling units are under h...

Page 8: ...s required the whole way around the machine to allow for sufficient ventilation The WL3 must not be installed in direct sunlight adjacent to a heat source or in an ambient room where the temperature i...

Page 9: ...he WL3 Firewall will then begin to cool and heat 12 The water temperatures are pre set at the factory to 5 c for the cold water and 87 c for the hot water 13 The water should now be taste tested any h...

Page 10: ...ock 7 1 4 Pushfit Outlet Your WL3 is generally ready for use Dispensing your choice of water is very simple as follows 1 Place your cup centrally in the dispensing area 2 Select the type of water you...

Page 11: ...he button starts flashing This means that the water is now heating to the extra hot temperature Once the button stops flashing press and hold the hot water button and simultaneously press the ambient...

Page 12: ...Firewall housing and the quartz spiral 8 Check the spiral for any scale build up and clean were necessary 9 Examine the UV loom for any discolouration or wear if there is any visible remove the loom a...

Page 13: ...removing the UV lamp Inspect the spiral for any damage or calcium build up if there is a large amount of calcium remove and replace the spiral and send it away to be treated by an ultrasonic bath 11 U...

Page 14: ...re to the WL3 Firewall is 45 PSI Check the filters are not partially blocked that the solenoid valves function correctly hot tank calcium build up need to be de scaled cold tank ice build up needs to...

Page 15: ...FS CAS WL3 M HCA WL3 M CA WL3 M CAS Machine Size 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 460mm D x 486mm H 385mm...

Page 16: ...o the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the grow...

Page 17: ...id Valve DC24V 1000mm 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 PI0308S 15 1 4 PE Pipe 16 Water Pressure Pump DC24 Daehwa 17 1 4 PE Pipe 18 JG Equal Elbow Connector 1 4 PI0308S 19...

Page 18: ...Elbow Connector 1 4 PI0308S 36 Solenoid Valve DC24V 1000mm 37 1 4 PE Pipe 38 1 4 PE Pipe 39 1 4 PE Pipe 40 JG Equal Elbow Connector 1 4 PI0308S 41 JG Equal Tee Connector 1 4 42 FW Assm 43 JG Equal El...

Page 19: ...ite WL650 universal as ST 8011 16 JG Equal Elbow Connector 1 4 PI0308S 17 Solenoid Valve DC24V 1000mm 18 JG Equal Elbow Connector 1 4 PI0308S 19 JG Equal Elbow Connector 1 4 PI0308S 20 Solenoid Valve...

Page 20: ...ual Elbow Connector 1 4 PI0308S 68 JG Equal Straight Connector 1 4 69 Wire Condenser WL650FS 70 13W UV Lamp UV and wire and plastic connector assembled N Part Description 31 Universal FS Filter Bracke...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Canada and Mexico info waterlogicusa com 1 402 884 72...

Reviews: