background image

WL3 Technical Manual - Version 1, July 2014

24

25

3. 

Measure 45ml of Aqua Dosa sanitising fluid into the empty filter housing and 

securely fasten the filter head.

4. 

Insert the water feed pipe into the inlet fitting of the inline filter housing containing 

sanitisation fluid. Attach a length of ¼” water pipe into the outlet fitting and insert 

the other end of the pipe into the bulkhead at the rear of the machine.

5. 

Remove the filter cartridge from the filter inside of the machine to avoid the 

mixing of sanitisation fluid and the active carbon, reattach the filter head securely. 

(The filter head can also be bypassed during sanitisation)

6. 

The water supply to the machine can now be turned on.

7. 

Dispense cold water until the sanitisation fluid leaves the faucet, this can be 

checked by pressing the cold button until the colour of the test strip has changed to 

indicate the presence of the Sani fluid (Normally about 400-500ml of water needs 

to be dispensed). If the machine has a carbonated option depress the cold button 

until 200ml of water has been dispensed and then depress the carbonated button 

and dispense the same amount of water, use the test strips to ensure the sanitisation 

fluid has reached the cold and the sparkling tanks. Do not let any sanitisation fluid 

enter the hot tank.

8. 

Leave the sanitisation fluid inside the machine for a minimum of 10-15 minutes, 

when this time has been reached, flush water through the machine until there is 

no sanitisation fluid left inside. Fit a new filter cartridge into the internal filter and 

remove the empty filter housing from the back of the machine, connect the water 

feed pipe directly into the bulkhead and turn the water supply on.

9. 

Inspect the faucet nipple and clean or replace if it is damaged or if there is a 

calcium build up around it.

10. 

Isolate power to the machine, then remove the quartz spiral by undoing the 

three screws on the top of the Firewall housing, disconnecting the UV sensor and 

water pipe, and removing the UV lamp. Inspect the spiral for any damage or calcium 

build up, if there is a large amount of calcium remove and replace the spiral and 

send it away to be treated by an ultrasonic bath.

11. 

Using the antibacterial wipes, sufficiently clean the exterior panels of the machine, 

including the drip tray and grill.

DE-SCALING

You will need the following items to descale the hot tank.

• 

A container that can hold 5 litres of water 

• 

Funnel or squeeze bottle

• 

Syringe

• 

Star/Phillips screwdriver 

• 

Descaling solution

1. 

Allow the machine to heat the water up to normal operating temperature, as the 

water inside the tank needs to be hot for the descaling solution to work effectively 

(Scale Kleen)

2. 

Isolate the power by disconnecting the power lead at the rear of the machine. 

Remove the top cover from the machine by undoing the two screws at the back of 

the lid and lift the panel in an upward motion.

3. 

Disconnect the silicone tubing from the faucet nipple, leave the other end attached 

to the outlet at the top of the hot tank.

4. 

Drain 50-100ml of hot water from the machine into a container, using the drainage 

valve at the rear of the machine. Then use the hot water from the machine to make 

your descaling solution, following the manufacturer’s instructions of the descaler.

5. 

If you are using a syringe then draw up the solution into the syringe and insert 

it into the open end of the silicone tubing, this should be done slowly as doing this 

process too quickly can result in the tank overflowing. If doing this with a funnel use 

the same process except you will pour the solution into the funnel connected to the 

silicone tube, add the solution in stages to prevent the hot tank overflowing.

6. 

Allow the solution to remain in the tank for 5 – 10 minutes, re-attach the silicone 

tubing to the faucet nipple, replace the top cover and then re-connect the power 

lead, and flush through the hot tank by dispensing water from the hot option. You 

will need to flush approx. 4-8 litres of water.

7. 

Open the top cover and check for leaks and then replace the top cover and 

secure it using the two screws

8. 

Smell and then taste the water and flush more water through the tank if needed. 

Summary of Contents for WL3 Firewall

Page 1: ...WL3 Firewall Technical Manual...

Page 2: ...ent not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses and by cli...

Page 3: ...ore the Activated Carbon process will remove a whole range of contaminants e g chlorine and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achie...

Page 4: ...ation tank at a minimum pressure of 3 2 bar This pressure is required to overcome the internal pressure from the CO2 gas which is in the tank IN FAUCET UV The Unique design allows the faucet area to b...

Page 5: ...VALVE WATER IN SPARKLING WATER OUT SOLENOID VALVE PUMP CHECK VALVE CO2 In SPARKLING TANK SAFETY VALVE COLD SENSOR COLD TANK SUCK BACK SOLENOID VALVE CHECK VALVE HOT WATER OUT HOT WATER OUT AIR VENT S...

Page 6: ...VALVE SOLENOID VALVE SPARKLING WATER OUT COLD SENSOR COLD TANK SOLENOID VALVE SUCK BACK SOLENOID VALVE CHECK VALVE AMBIENT WATER OUT COLD WATER OUT SOLENOID VALVE Wetted Parts Layout Cold Ambient and...

Page 7: ...als could present a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used CO2 gas cylinders used for sparkling units are under h...

Page 8: ...s required the whole way around the machine to allow for sufficient ventilation The WL3 must not be installed in direct sunlight adjacent to a heat source or in an ambient room where the temperature i...

Page 9: ...he WL3 Firewall will then begin to cool and heat 12 The water temperatures are pre set at the factory to 5 c for the cold water and 87 c for the hot water 13 The water should now be taste tested any h...

Page 10: ...ock 7 1 4 Pushfit Outlet Your WL3 is generally ready for use Dispensing your choice of water is very simple as follows 1 Place your cup centrally in the dispensing area 2 Select the type of water you...

Page 11: ...he button starts flashing This means that the water is now heating to the extra hot temperature Once the button stops flashing press and hold the hot water button and simultaneously press the ambient...

Page 12: ...Firewall housing and the quartz spiral 8 Check the spiral for any scale build up and clean were necessary 9 Examine the UV loom for any discolouration or wear if there is any visible remove the loom a...

Page 13: ...removing the UV lamp Inspect the spiral for any damage or calcium build up if there is a large amount of calcium remove and replace the spiral and send it away to be treated by an ultrasonic bath 11 U...

Page 14: ...re to the WL3 Firewall is 45 PSI Check the filters are not partially blocked that the solenoid valves function correctly hot tank calcium build up need to be de scaled cold tank ice build up needs to...

Page 15: ...FS CAS WL3 M HCA WL3 M CA WL3 M CAS Machine Size 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 460mm D x 486mm H 385mm...

Page 16: ...o the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the grow...

Page 17: ...id Valve DC24V 1000mm 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 PI0308S 15 1 4 PE Pipe 16 Water Pressure Pump DC24 Daehwa 17 1 4 PE Pipe 18 JG Equal Elbow Connector 1 4 PI0308S 19...

Page 18: ...Elbow Connector 1 4 PI0308S 36 Solenoid Valve DC24V 1000mm 37 1 4 PE Pipe 38 1 4 PE Pipe 39 1 4 PE Pipe 40 JG Equal Elbow Connector 1 4 PI0308S 41 JG Equal Tee Connector 1 4 42 FW Assm 43 JG Equal El...

Page 19: ...ite WL650 universal as ST 8011 16 JG Equal Elbow Connector 1 4 PI0308S 17 Solenoid Valve DC24V 1000mm 18 JG Equal Elbow Connector 1 4 PI0308S 19 JG Equal Elbow Connector 1 4 PI0308S 20 Solenoid Valve...

Page 20: ...ual Elbow Connector 1 4 PI0308S 68 JG Equal Straight Connector 1 4 69 Wire Condenser WL650FS 70 13W UV Lamp UV and wire and plastic connector assembled N Part Description 31 Universal FS Filter Bracke...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Canada and Mexico info waterlogicusa com 1 402 884 72...

Reviews: