2.
Water does not dispense from Unit
Possible Reason
Solution
Too much water pressure.
Recommend 40‐60 psi for the
WL250 Water Treatment
System
to operate properly.
The correct input water pressure is critical to the
performance of the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water
pressure gauge.
Additional method of verification is to turn off water to unit
and press the dispense button. Does the solenoid open
without water pressure to the unit? Listen for solenoid to
activate, not button “click”.
Adjust water pressure to 40‐60 psi.
Closed water supply valve
Open the water supply valve.
The unit is not properly
plugged into electrical outlet
Check electrical outlet connection, or for blown circuit
breaker.
Red Heater and Compressor
Switch on unit is in the off
position
Turn Red Heater and Compressor switch on.
I = ON
15 Amp Fuse Blown
Replace the 15 Amp Fuse as needed.
Water is present in the bottom
tray, causing the leak
detection to trigger.
*Leak Detection is on the
Counter Top Model only.
Remove the Top Cover and Front Panel. Tip the unit slightly
to drain, dry bottom tray completely.
Hot and Cold Solenoid
connections into the Display
PCB are loose.
Turn power off; unplug the unit and visually inspect solenoid
connections into the Display PCB. Verify the soldering points
on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.