background image

10

11

Waterlogic 100 Technical Manual - Issue B, September 2011

Installation Procedures

IMPORTANT NOTICE: 

This procedure should only be carried out by a technician trained by waterlogic 

international or by an approved distributing agent.
Note: This appliance is intended for indoor use only. Cleaning of Waterlogic prod-

ucts should not be carried out using a jet washer.

1. 

Mount the WL100 on a firm flat surface with a 50mm air gap on both sides and top 

so that it cannot topple or fall from a counter top.

2.

 It is advisable that the water and electricity supply are within two meters of the 

WL100 and that the water isolation valve and power supply are accessible. The 

WL100 should not be installed using an extension lead. The water supply should be 

from a potable source.

3.

 Level the machine using the adjustable feet.

4.

 Remove the top cover of the machine. If you are installing a freestanding machine 

also remove the lower front cover. This is retained by two screws located under the 

front edge at the bottom of the cover and two clips in the same location. Remove 

the screws and push clips up to release. To gain access to the screws tilt the ma-

chine backward at an angle of 10 degrees.

5.

 Make the water connection using an installation kit. Waterlogic recommends the 

use of a pressure reducing valve, and shut off valve and a non return valve. These 

should be fitted before the water intake to the machine. Minimum operating pres-

sure for the machine to work suitably is 2.5 bar. The ideal operating pressure is at 3 

bar. At pressures higher than 3 bar the machine will not function correctly and can 

lead to leaks.

6

. Please flush the water supply pipe until it runs clear, before making the water con-

nection to the rear of the machine.

7.

 The power lead is located in a recess on the top packing cover of the machine re-

gardless whether it is a mini or a free standing model. Inspect the electrical socket, 

the machine plug and the power cable for any transit damage. Now plug the power 

lead into the back of the machine. As soon as you plug the machine into a suitable 

power supply, voltage will be available to the PCB and solenoid valves and you can 

now start to flush water through the machine. Do not at this point turn on the heater 

and compressor switch at the rear of the machine. This switch should only be turned 

on once the hot tank is filled with water.

8. 

The hot water temperatures is set at 85°C and the cold water temperatures is 

set at 5°C at the factory. It is not possible to adjust the hot water temperature, but 

the cold water temperature can be adjusted by regulating the thermostat situated 

at the back of the machine. This thermostat is set at a specific point at the factory. 

This point is marked out by a small dot situated on the outside of the thermostat. It 

is advised that you do not adjust the cold thermostat past the factory set point of 

5°C as this may result in the system freezing. 

9. 

If installing a hot and cold model, do the following. Alternatively go to point 11.

10. 

Select the hot water option and press the dispense button to start flushing wa-

ter through the machine filter and hot tank. The filter will produce carbon fines at 

first and the water may have a black appearance. Continue to flush 10 litres of water.

11. 

Select the cold water option and press the dispense button and flush for 10 litres 

of water through the cold tank. If you are installing a cold only machine then flush for 

20 litres. This will generate the filter and clean any residual water from the machine.

12.

 Check the machine for any water leaks and ensure that all water fittings are se-

cured properly.

13.

 Once you are satisfied that water is passing through both the hot and cold tank 

successfully then turn on the heater/compressor switch at the back of the machine. 

The machine will now start to heat and chill.

Summary of Contents for WL100

Page 1: ...Waterlogic 100 Technical Manual Issue B September 2011 WL100 Technical Manual...

Page 2: ...es PDI 9 Installation Procedures 10 Operating Instructions 14 Maintenance and Servicing 16 Sanitising or Descaling 17 Fault Finding 18 Technical Specifications and Warranties 20 End of Life 22 ROHS 22...

Page 3: ...The water is stored in the Cold Tank The cold tanks temperature is controlled by a thermostat that is set at the factory The thermostat set point is marked at the back of the machine by a small dot H...

Page 4: ...Free Standing model and 50 grams of R134a gas for the Mini Model WATER PIPE AND FITTINGS The inlet and the internal water circuit pipe sizes used are 1 4 and 5 16 The entire internal water circuit an...

Page 5: ...ecautions should be taken 6 Flush water through the hot tank first until the water runs clear of any carbon fines Approximately 10 litres should be flushed through the filters 7 Now flush water throug...

Page 6: ...chine re gardless whether it is a mini or a free standing model Inspect the electrical socket the machine plug and the power cable for any transit damage Now plug the power lead into the back of the m...

Page 7: ...e flushed and sanitised every 6 months Waterlogic International strongly recommends the use of an anti flood device Figure 1 is the recommended installation kit Fig 1 Recommended Installation Kit 14 T...

Page 8: ...utton continuously until cup is full Never try to fill more than one vessel at a time COLD WATER Push the cold water button blue Cold water dispenses HOT water Push the 2 hot red buttons together Hot...

Page 9: ...hot tank Let the WL100 stand for a minimum of 15 minutes and then flush out the sanitizing solution Replace or refit the filters remove the empty filter housing and reconnect the water supply to the W...

Page 10: ...l fault finding procedures must be carried out by a technician trained by Waterlogic International or their nominated distributor Please take great care and suitable health and safety measures when fa...

Page 11: ...rranties SAFETY Subject to the standard terms and conditions of sale a copy of which has been provided to you neither Waterlogic International Limited Waterlogic nor any affiliated companies shall be...

Page 12: ...into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the g...

Page 13: ...ue Tube ST 11 1 4 Equal Tee Connector ST 12 Solenoid Valve 24DC Single 13 1 4 Blue Tube ST 14 5 16 X1 4 Reducing Elbow Connector ST 15 JG LLDPE Tube Blue 8mm PE 0806 100M B 16 2Liter cold tank 17 JG L...

Page 14: ...et for Plug Connection 7 Gasket for Power Socket 8 Side Panel 9 Plastic Handel 10 Plastic Cap for 1 4 Bulkhead Fitting 11 JG Bulkhead Connector Union 1 4 1 4 12 Compressor R134a 1 8HP 220 240V 50 60Hz...

Page 15: ...rip Tray Insert 27 Plastic PCB Cover 28 PCB for WL100 29 Front Hatch Panel 30 Silicon Button Key Mat 31 Button Cover 32 Label 33 Drip Tray Grill 34 Drip Tray Body 35 Power Transformer UV 220V 50Hz 36...

Page 16: ...Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Ca...