6
7
Waterlogic 100 Technical Manual - Issue B, September 2011
FILTERS
The filtration system on the WL100 is designed to reduce dirt and sediment
particles from the water. Furthermore, the Activated Carbon process will remove
a whole range of contaminants e.g. chlorine and pesticides.
There are many kinds of different filter combinations available from Waterlogic
to suit local water conditions
PCB
The PCB (Printed Circuit Board) is the control unit for the WL100 which is
responsible for the functions of all the mechanical and electrical parts (24V DC).
There are two PCB’s in this unit: a Display PCB and a Sleep Mode PCB for the
hot option.
COMPRESSOR
The compressor operates at 220-240V at 50Hz. It uses 60 grams of R134a non-
Ozone depleting refrigerant gas for the Free Standing model and 50 grams of
R134a gas for the Mini Model.
WATER PIPE AND FITTINGS
The inlet and the internal water circuit pipe sizes used are 1/4” and 5/16”. The
entire internal water circuit and all the components which come in contact with
water are food grade NSF / WRAS approved products.
WATER VALVES
Dispensing of water to the customer is achieved by means of a 24V DC electrical
solenoid valve. The valves are energized every time the customer pushes the
dispense button for a drink. DC voltage is used to give a positive and quieter
action of the solenoid valve.
PLASTIC PANELS
The moulded panels are made from recyclable ABS plastic. All the ABS plastic
panels are UV resistant and meet the standards of CE and UL. Please note
that the WL100 should not be exposed to direct sunlight. Placing the WL100 in
direct sunlight from a window, close to a radiator, or in a room of high ambient
temperature, will affect the efficiency of the refrigeration system.