20
21
Waterlogic 1000 GF Technical Manual - Issue A, July 2011
INSTALLATION KIT
Waterlogic recommend that you use a Waterlogic installation kit that includes a
pressure reducer set to 45 PSI, a non-return valve, a Waterlogic block leak shut off
and this Technical Manual. Allow 1 hour to complete installation.
• The WL 1000 GF must be installed according to the local guidelines.
• Waterlogic strongly recommend that a pressure reducing valve set at 3 bar
and a non-return valve be used on all WL 1000 GF installations.
• The WL 1000 GF should not be connected to water supplies of unknown
bacterial quality or those not already fit for human consumption.
The WL 1000 GF should only be connected to a Potable drinking water supply.
• The pre-sediment and carbon filters on the WL 1000 GF must be changed
every 6 months.
• The UV lamp on the WL 1000 GF must be changed every 6 months.
• The cold tank and header tank should also be flushed and sanitised
every 6 months.
• Waterlogic International strongly recommends the use of an anti-flood device.
• Figure 1 is the recommended installation kit.
Fig 1. Waterlogic Installation Kit
Dispensing your choice of water is very simple, as follows:
1.
Place your cup under the required faucet in the dispensing area
2.
Select the type of water you wish to be dispensed and press the corresponding
button.
3.
Keep the button depressed until your cup has reached the desired level,
and then release the button.
4.
Whist the dispense button is depressed water will flow until the button is
released.
There are 3 faucet points on the 1000 GF. The cup must be placed under
the correct faucet before pushing the coloured dispensing button.
Operating Instructions
HOT
COLD
ROOM