P2 Classe
Manual
Page 8 – Revision: 3-2-2021
MODEL/PART DESIGNATIONS
BRAND NAME
DESCRIPTION
MODEL -
PART NUMBER
P2 Classe
P2 Classe
–
Cold, Cold Sparkling
CLASSE P2
F-P2FX-M-CS-IB-SB-WLU
Serial Number: TP2C425SBXXX
SPECIFICATIONS
ITEM
P2 CLASSE
Water Connection
1/4” Quick Connect
Cold Water Temperature
Cold Water Temperature – Factory Set Point 5°C (41°F)
Sparkling Tank Capacity
1 Liter
Ice Bath Capacity
21 Liters
Recommended Service
Pressure
43-60 psi (275-414 kPa) – Use Pressure Regulator
Recommended CO
2
Service
Pressure
50-60 psi (345-414 kPa) – Use Pressure Regulator
Rated Service Flow - Cold
2.0-3.0 Liters per Minute (0.5-0.8 Gallons per minute)
Rated Service Flow -
Sparkling
2.5-3.5 Liters per Minute (0.6-0.9 Gallons per minute)
Environmental Temperature 16° - 32°C (60° - 90°F)
UV Lamp (per Firewall)
15 W
Refrigerant Gas
R134a, 110g, 3.88 ounces
R134a Pressures
High (230 psi), Low (90 psi)