INSTALLATION AND FLUSHING PROCEDURES
Safety and Installation Guidelines
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are
met when installing
Waterlogic
Equipment. Only qualified service technicians should attempt
installation and service of
Waterlogic
Equipment.
WARNING!
ELECTRICAL SHOCK HAZARD.
Always unplug (isolate from power supply) to
prevent electrical shock except where electrical tests are specified.
WARNING!
IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK.
Connect to a 15 amp, 120V 60Hz properly grounded outlet (GFI is recommended). Ensure
polarity is correct and always use a 3-prong outlet. Consult a qualified electrician if you
have any questions.
WARNING!
USE ONLY Waterlogic SUPPLIED POWER CORD.
Locate system within 5 feet of
power supply. Never use an extension cord or adapter. Do not use a damaged power cord
or plug. Keep power cord out of heavy traffic areas and away from heat sources. Do not,
under any circumstances, remove ground prong or alter the power cord. Never pull the
power plug from the outlet with a wet hand or allow the plug to get wet. Failure to use the
supplied power cord will void UL Certification and Warranty.
CAUTION!
INDOOR USE ONLY.
Never expose to direct sunlight, heat sources, or ambient
air temperature above 38°C (100°F) or below 2°C (35°F). Install indoors and keep unit away
from excessive humidity. Never expose to freezing temperatures. Ensure there is adequate
clearance around the unit to allow refrigeration system condenser to dissipate heat.
Warmer environments require more clearance around the unit. Minimum clearance around
all surfaces of the machine is 2-inches. Installs where the ambient temperature exceeds
80°F, require a minimum of 4-inches clearance for proper heat dissipation and efficient
operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for
injury or damage caused by excessive water pressure. Operating pressure must be 40 psi to
60 psi. Be aware any of potential pressure surges caused by building/municipal pumping
stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or
cold-water supply only.
Feed water over 100° F (37°C) can damage the treatment
components. Water block devices and external leak detectors are strongly recommended.
Locate the unit as close to the water supply and the electrical connections as possible.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and
reduce microbiological contamination (potential bacterial growth). Sanitize before use to
eliminate any potential microbiological contaminates